Heat generation during osteotomy performed with ultrasonic insert versus rotary instrument in bovine femur: ex vivo comparison
Acta Odontológica Latinoamericana · 2025
DOI: 10.54589/aol.38/1/5 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Acta Odontológica Latinoamericana, 2025. Verfasst von Jéssica B Borges und 5 weiteren Autor:innen. Beteiligte Einrichtung: Faculdade de Odontologia São Leopoldo Mandic, Departamento de Implantodontia. Campinas, SP, Brasil. jessica.bb@live.com. Hauptthemen laut MEDLINE: Osteotomy, Femur, Hot Temperature. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Osteotomy procedures in dentistry are usually performed with drills, but piezosurgical instruments have also been used to improve surgical conditions for both the patient and the operator. This ex vivo study uses infrared thermography to analyze heat generation in osteotomies.
Aim
The aim of this study was to conduct an infrared thermographic comparison of the heat generated by an ultrasonic insert, either with or without an aerosol dispersion control device, in contrast to a conventional bur, during osteotomy procedures performed on bovine femur specimens. Materials and Method: Osteotomies were performed on nine bovine femur blocks, with each osteotomy consisting of a linear cut 12 mm long and 3 mm deep. Each block underwent a single cut from each instrument examined. The osteotomies were divided into three groups according to the instrument used: Group CARB, carbide bur #701; Group INS, #SFR4 ultrasonic insert coated with diamond-like carbon (DLC); and Group INS-S, #SFR4 ultrasonic insert coated with DLC in combination with an aerosol dispersion control device (“spray control”). All incisions were standardized using an automated device. Thermal variations (ΔT) were assessed using an infrared thermographic camera. The maximum (Tm) and minimum (T0) temperatures recorded were utilized to calculate ΔT, following the equation: ΔT = Tm – T0. Statistical analyses were conducted using Kruskal- Wallis test and Dunn’s test for multiple comparisons (p < 0.05).
Results
The T0 and Tm recorded for INS (21.5°C ± 0.7ºC and 23.2ºC ± 0.7ºC) and INS-S (20.8ºC ± 0.4ºC and 21.8ºC ± 0.4ºC) were significantly higher (p < 0.05) than for CARB (14.9ºC ± 0.8ºC and 17.6ºC ± 1.1ºC, respectively). The observed ΔT for INS (1.7ºC ± 0.4ºC) and INS-S (1.0ºC ± 0.4) were significantly lower (p < 0.05) than for CARB (2.7ºC ± 1.1ºC). No significant difference in ΔT was observed for the other comparisons.
Conclusion
INS and INS-S produced significantly higher temperatures than CARB. Use of the “spray control” device resulted in a reduction of the temperature variation observed for the piezoelectric insert.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Faculdade de Odontologia São Leopoldo Mandic, Departamento de Implantodontia. Campinas, SP, Brasil. jessica.bb@live.com.
- Faculdade de Odontologia São Leopoldo Mandic, Departamento de Implantodontia. Campinas, SP, Brasil.
- Department of Oral & Maxillofacial Surgery, University of California, Los Angeles, USA.
ORCID-Profile: Jéssica B Borges, Antonio C Aloise, Luis Gs Macedo, Marcelo L Teixeira, Peter K Moy, André A Pelegrine
Zitieren
APA
Borges, J. B., Aloise, A. C., Macedo, L. G., Teixeira, M. L., Moy, P. K., & Pelegrine, A. A. (2025). Heat generation during osteotomy performed with ultrasonic insert versus rotary instrument in bovine femur: ex vivo comparison. Acta Odontológica Latinoamericana. https://doi.org/10.54589/aol.38/1/5
Vancouver
Borges JB, Aloise AC, Macedo LG, Teixeira ML, Moy PK, Pelegrine AA. Heat generation during osteotomy performed with ultrasonic insert versus rotary instrument in bovine femur: ex vivo comparison. Acta Odontológica Latinoamericana. 2025. doi:10.54589/aol.38/1/5
BibTeX
@article{Borges2025,
author = {Borges, Jéssica B and Aloise, Antonio C and Macedo, Luis Gs and Teixeira, Marcelo L and Moy, Peter K and Pelegrine, André A},
title = {Heat generation during osteotomy performed with ultrasonic insert versus rotary instrument in bovine femur: ex vivo comparison},
journal = {Acta Odontológica Latinoamericana},
year = {2025},
doi = {10.54589/aol.38/1/5}
}
EUVIMED