Effect of two oxygen-inhibiting agents on the surface microhardness of giomer restorative materials
Acta Odontológica Latinoamericana · 2024
DOI: 10.54589/aol.37/2/99 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Acta Odontológica Latinoamericana, 2024. Verfasst von Diana J De La Cruz und 1 weiteren Autor:innen. Beteiligte Einrichtung: Universidad Científica del Sur, Lima, Lima, Perú. Hauptthemen laut MEDLINE: Surface Properties, Materials Testing, Oxygen, Hardness. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Giomers are bioactive hybrid restorative materials consisting of composite resin and glass ionomer filler pre-reacted on the surface, which maintain acceptable clinical qualities over time. One of the main factors that explains this is the surface hardness that is achieved by inhibiting the oxygen layer.
Aim
To compare the effect of blue and conventional Mylar strips used as oxygen inhibiting agents on the surface microhardness of giomer restorative materials. Materials and Method: A total 96 giomer specimens were prepared in disc-shaped molds 2 mm tall x 5 mm in diameter (ISO 4049: 2019-05). The specimens were grouped according to type of giomer: Beautifil II (BII) or Beautifil II LS (BIILS), and according to the type of Mylar strip: conventional, blue, or control group without strip. They were subsequently subjected to the Knoop (KHN) microhardness test. The database was analyzed with Stata SE v18 statistical software, and two-way ANOVA was performed.
Results
Interaction was found between the type of giomer and Mylar strip (p=0.039). Significant differences were found between surface microhardness values according to the type of giomer (0.001) and the type of Mylar strip (0.001). Beautifil II LS presented significant differences between conventional Mylar strip vs. without Mylar strip (43.58 ± 1.65 vs. 40.44 ± 2.12) and between blue Mylar strip and without Mylar strip (44.69 ± 1.75 vs. 40.44 ± 2.12). In the Bonferroni Post hoc test, a significant difference was found between Conventional Mylar Strip and without Mylar Strip (p=0.001) and Blue Mylar Strip and without Mylar Strip (p=0.001).
Conclusion
The use of blue and conventional Mylar strips inhibits the oxygen layer on the Beautifil II and Beautifil II LS giomers, endowing them with high values of surface microhardness.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Universidad Científica del Sur, Lima, Lima, Perú.
ORCID-Profile: Diana J De La Cruz, Melvin Cisneros-Del Águila
Zitieren
APA
De La Cruz, D. J., & Cisneros-Del Águila, M. (2024). Effect of two oxygen-inhibiting agents on the surface microhardness of giomer restorative materials. Acta Odontológica Latinoamericana. https://doi.org/10.54589/aol.37/2/99
Vancouver
De La Cruz DJ, Cisneros-Del Águila M. Effect of two oxygen-inhibiting agents on the surface microhardness of giomer restorative materials. Acta Odontológica Latinoamericana. 2024. doi:10.54589/aol.37/2/99
BibTeX
@article{DeLaCruz2024,
author = {De La Cruz, Diana J and Cisneros-Del Águila, Melvin},
title = {Effect of two oxygen-inhibiting agents on the surface microhardness of giomer restorative materials},
journal = {Acta Odontológica Latinoamericana},
year = {2024},
doi = {10.54589/aol.37/2/99}
}
EUVIMED