D-dimer as a sensitive and a very nonspecific parameter for the diagnosis of pulmonary embolism

Mirza Halilcevic, Alen Tvica, Dalila Halilcevic, Svjetlana Mujagic, Nihad Mesanovic, Zlatan Mehmedovic, Hajrudin Kozarevic, Bozo Juric, Azemina Salihodzic, Alma Gulamovic, Anja Divkovic, Sefika Umihanic und 1 weitere

Acta Medica Saliniana · 06.03.2025 · 54 (2)

DOI: 10.5457/ams.v54i2.773 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Acta Medica Saliniana, online erschienen am 06.03.2025. Verfasst von Mirza Halilcevic und 12 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Since the beginning of the Covid-19 pandemic there has been an immense increase of CT pulmonary angiogram (CTPA) requests at the department of Radiology at our hospital. One of the most significant complications of Covid-19 is pulmonary embolism. The gold standard for detecting pulmonary embolism is CTPA.

Aim

The aim of this study was to evaluate if an elevated value of D-dimer in both Covid-19 and non- Covid-19 patients, is reason enough for patients to undergo CTPA.

Methods

CTPA was used for PE evaluation. PCR testing was used in order to separate patients into positive and negative Covid-19 groups. Plasma D-dimer levels were measured using the BCS XP Siemens System.

Results

There is no equivalent statistical form of changes in the values of the treated indicators (D-dimer levels, PCR tests, and PE (Pulmonary Embolism) present or not). According to the calculated Pearson’s, Spearman’s, and Kendall’s correlation coefficients, there is a very small correlation between D-dimer levels, PCR tests, and PE. Both Covid-19 and non-Covid-19 patients below the threshold of 0,5µg/mL, should not be considered for CTPA. Testing the sensitivity and specificity values at different cut-offs, provided us with an increase in specificity at higher cut-off values, but also a significant decrease in sensitivity.

Conclusions

D-dimer levels should be more often in correlation with clinical tests, since it has a low specificity for pulmonary embolism even at different cut-off values.

Zitieren

APA

Halilcevic, M., Tvica, A., Halilcevic, D., Mujagic, S., Mesanovic, N., Mehmedovic, Z., Kozarevic, H., Juric, B., Salihodzic, A., Gulamovic, A., Divkovic, A., Umihanic, S., & Fazlic, E. (2025). D-dimer as a sensitive and a very nonspecific parameter for the diagnosis of pulmonary embolism. Acta Medica Saliniana, 54(2). https://doi.org/10.5457/ams.v54i2.773

Vancouver

Halilcevic M, Tvica A, Halilcevic D, Mujagic S, Mesanovic N, Mehmedovic Z, et al. D-dimer as a sensitive and a very nonspecific parameter for the diagnosis of pulmonary embolism. Acta Medica Saliniana. 2025;54(2). doi:10.5457/ams.v54i2.773

BibTeX
@article{Halilcevic2025,
  author = {Halilcevic, Mirza and Tvica, Alen and Halilcevic, Dalila and Mujagic, Svjetlana and Mesanovic, Nihad and Mehmedovic, Zlatan and Kozarevic, Hajrudin and Juric, Bozo and Salihodzic, Azemina and Gulamovic, Alma and Divkovic, Anja and Umihanic, Sefika and Fazlic, Emir},
  title = {D-dimer as a sensitive and a very nonspecific parameter for the diagnosis of pulmonary embolism},
  journal = {Acta Medica Saliniana},
  year = {2025},
  volume = {54},
  number = {2},
  doi = {10.5457/ams.v54i2.773}
}
Kostenlos starten →