EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Comparing the use of High Performance Liquid Chromatography (HPLC) and Spectrophotometry to measure the amount of chitosan in water-soluble fertilizers

Junming Huang, Xiaona Hou, Mi Liu, Yansong Han, Wankui Bao, Xu Wang, Hongfang Liu

Advances in Analytic Science · 2022

DOI: 10.54517/aas.v3i1.1991 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advances in Analytic Science, 2022. Verfasst von Junming Huang und 6 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref). Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Several analytical techniques, including High Performance Liquid Chromatography (HPLC) and Spectrophotometry, were developed to quantify the chitosan content in water-soluble fertilizers, with a focus on optimizing the hydrolysis conditions for chitosan. The results showed that the optimal hydrolysis was found to occur using a 1+1 hydrochloric acid solution at 100°C for 24 hours. For HPLC, using 1-phenyl-3-methyl-5-pyrazolone (PMP) as the derivatizing agent, the method exhibited a linear range of 1-200 mg/L, a detection limit of 0.07 mg/L, and a spiked recovery rate of 95%-101%. Spectrophotometry, on the other hand, had a linear range of 0-100 μg, a detection limit of 0.47 μg, and a recovery rate of 94%. The two methods demonstrated good agreement in their determination of chitosan content in water-soluble fertilizer samples, satisfying the analytical requirements for chitosan in such fertilizers. HPLC proved to be more efficient with fewer interference factors. Additionally, the use of methyl fluorene chloroformate (FMOC-Cl) as a derivatizing agent for chitosan hydrolysate, followed by detection with HPLC, yielded results that were essentially consistent with the previous two methods. However, the HPLC and spectrophotometry methods established in this study were not suitable for determining chitosan content in water-soluble fertilizers that contain nitrates.

Zitieren

APA

Huang, J., Hou, X., Liu, M., Han, Y., Bao, W., Wang, X., & Liu, H. (2022). Comparing the use of High Performance Liquid Chromatography (HPLC) and Spectrophotometry to measure the amount of chitosan in water-soluble fertilizers. Advances in Analytic Science. https://doi.org/10.54517/aas.v3i1.1991

Vancouver

Huang J, Hou X, Liu M, Han Y, Bao W, Wang X, et al. Comparing the use of High Performance Liquid Chromatography (HPLC) and Spectrophotometry to measure the amount of chitosan in water-soluble fertilizers. Advances in Analytic Science. 2022. doi:10.54517/aas.v3i1.1991

BibTeX
@article{Huang2022,
  author = {Huang, Junming and Hou, Xiaona and Liu, Mi and Han, Yansong and Bao, Wankui and Wang, Xu and Liu, Hongfang},
  title = {Comparing the use of High Performance Liquid Chromatography (HPLC) and Spectrophotometry to measure the amount of chitosan in water-soluble fertilizers},
  journal = {Advances in Analytic Science},
  year = {2022},
  doi = {10.54517/aas.v3i1.1991}
}
Kostenlos starten →