Optimizing ultrasound Doppler measurement precision: a comprehensive experimental approach
Technobius Physics · 2024
DOI: 10.54355/tbusphys/2.2.2024.0011 ↗Kurz gefasst
Fachartikel in der Zeitschrift Technobius Physics, 2024. Verfasst von Alima Aidarbek. Die Arbeit nennt 11 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Corrigendum Notice: A corrigendum has been issued for this article and is included at the end of this document. Referred to by: “A. Aidarbek “Optimizing ultrasound Doppler measurement precision: a comprehensive experimental approach”, tbusphys, vol. 2, no. 2, p. 0011, Apr. 2024. doi: 10.54355/tbusphys/2.2.2024.0011”. Experimental studies were conducted utilizing advanced equipment comprising a generator, tubing system, pump module, sonographer, and PC. The generator serves as the central component connected by tubes to the pump, forming a closed circuit. A tee in the tubing set prevents Doppler fluid leakage, with the fluid poured through a special funnel into the circuit post-connection. The Doppler fluid is evenly mixed by shaking its bottle to enhance signal strength. The entire system is sealed. The centrifugal pump generates continuous flows; different power modes were tested for 30 minutes each, with frequency shifts measured at angles α=15°, 30°, and 60°. Pump disconnection from the power supply prevents liquid entry during tubing connection. The pump module housing includes ventilation holes. A 3 by 8 cm Doppler prism, treated with ultrasonic gel, was connected to the tubing to capture data. A sonographer emitting signals at 2 MHz, with a gain range of 10 to 40 dB, was utilized for sound spectra analysis. High-mode operation, 4 microseconds pulse duration, and a 32 microseconds receiver gate were set. The ultrasound apparatus dimensions were 230 x 236 x 168 mm, with a power consumption of 27 VA. Data visualization was facilitated by an LED panel, with adjustable acoustic signal volume. A USB interface enabled connection to a PC for ease of use and data analysis. Special software facilitated graph generation depicting frequency vs. time dependence measurements. Frequency analysis yielded average and maximum frequency values, with f-mean utilized to measure Doppler effect frequency shift.
Zitieren
APA
Aidarbek, A. (2024). Optimizing ultrasound Doppler measurement precision: a comprehensive experimental approach. Technobius Physics. https://doi.org/10.54355/tbusphys/2.2.2024.0011
Vancouver
Aidarbek A. Optimizing ultrasound Doppler measurement precision: a comprehensive experimental approach. Technobius Physics. 2024. doi:10.54355/tbusphys/2.2.2024.0011
BibTeX
@article{Aidarbek2024,
author = {Aidarbek, Alima},
title = {Optimizing ultrasound Doppler measurement precision: a comprehensive experimental approach},
journal = {Technobius Physics},
year = {2024},
doi = {10.54355/tbusphys/2.2.2024.0011}
}
EUVIMED