EUVIMEDEUVIMED entdecken
Crossref

Limbusreaktion nach Sklerallinsenanpassung

Tom Luis Platten, Sebastian Golczyk, Horst Drexel, Werner Eisenbarth

Optometry & Contact Lenses · 01.05.2026 · 6 (2) · 60-67

DOI: 10.54352/dozv.jhat6267 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Optometry & Contact Lenses, online erschienen am 01.06.2026. Verfasst von Tom Luis Platten und 3 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To investigate quadrant-specific changes in limbal tissue thickness after 7 days of scleral lens wear using anterior segment OCT (AS-OCT), and the associated changes in central corneal thickness (CCT), central epithelial thickness (CET), and central corneal clearance (CCC). Material and Methods. In this observational study, 20 eyes of 11 scleral lens neophytes (35 ± 12 years; 4 eyes with keratoconus) were fitted with a scleral lens. CCT and CET were measured with a swept-source AS-OCT system; limbal tissue thickness was determined in four quadrants at three locations each, and CCC was documented. Two baseline measurements on different days before lens wear and one measurement after 7 days of daily wear (≥ 8 h/day) were performed. Changes were analysed descriptively.

Results

After 7 days, CCT increased from 525.75 ± 55.24 µm to 537.48 ± 58.53 µm (Δ +11.73 µm), while CET remained unchanged from 51.31 ± 9.19 µm to 51.03 ± 9.03 µm (Δ −0.28 µm). The limbal area showed a quadrant-specific pattern: thickening up to +20.9 µm nasally, +32.3 µm temporally and +50.3 µm inferiorly contrasted with thinning up to −56.7 µm superiorly. CCC decreased from 288.4 ± 61.7 µm to 232.2 ± 56.0 µm (Δ −56.1 µm).

Conclusion

Seven days of scleral lens wear are associated with quadrant-specific changes in limbal tissue thickness, a small increase in CCT, stable CET and a moderate reduction in CCC, supporting limbal thickness as a potentially early-­responding structural parameter under scleral lenses.

Zitieren

APA

Platten, T. L., Golczyk, S., Drexel, H., & Eisenbarth, W. (2026). Limbusreaktion nach Sklerallinsenanpassung. Optometry & Contact Lenses, 6(2), 60-67. https://doi.org/10.54352/dozv.jhat6267

Vancouver

Platten TL, Golczyk S, Drexel H, Eisenbarth W. Limbusreaktion nach Sklerallinsenanpassung. Optometry & Contact Lenses. 2026;6(2):60-67. doi:10.54352/dozv.jhat6267

BibTeX
@article{Platten2026,
  author = {Platten, Tom Luis and Golczyk, Sebastian and Drexel, Horst and Eisenbarth, Werner},
  title = {Limbusreaktion nach Sklerallinsenanpassung},
  journal = {Optometry & Contact Lenses},
  year = {2026},
  volume = {6},
  number = {2},
  pages = {60--67},
  doi = {10.54352/dozv.jhat6267}
}
Kostenlos starten →