Intraoral Scanning Verse Custom Impression Coping for Implant Crowns
Journal of Dentistry and Oral Epidemiology · 06.05.2026
DOI: 10.54289/jdoe2600105 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Dentistry and Oral Epidemiology, online erschienen am 06.05.2026. Verfasst von Andrew S Ryser.
Abstract (Originalsprache)
Patients: A 26-year-old male reported to a dental clinic with an implant at the maxillary left central incisor with a provisional restoration. A treatment plan of a ceramic crown on a custom titanium abutment was planned.
Discussion
The soft tissue profile of the peri-implant zone is as significant as the implant restoration itself since soft tissue stability and management around osseointegrated implants are considered focal points for an esthetic success. When an implant is ready to be restored the contours and shape of the healed peri-implant tissue must be accurately recorded or the final restoration may fall short of the desired outcome. This critical information can be recorded via implant level impressions or intra-oral scanning. The accuracy of an impression with a custom impression coping compared to an intraoral scan after the provisional implant crown has been removed is unknown. This case report demonstrates the differences between a custom impression coping and an intraoral scan for a maxillary central incisor.
Conclusions
This article provides insight into the differences between a PVS impression utilizing a custom impression coping and an intraoral scanner and associated scan body and differences in tissue position. The analysis in this case presentation shows some collapse of the tissue when using the intraoral scanner when compared to a tissue supported PVS impression. More research is needed to critically study the collapse of the peri-implant tissue while utilizing intraoral scanners and development of a technique that would prevent collapse of the peri-implant tissue when using an intraoral scanner
Zitieren
APA
Ryser, A. S. (2026). Intraoral Scanning Verse Custom Impression Coping for Implant Crowns. Journal of Dentistry and Oral Epidemiology. https://doi.org/10.54289/jdoe2600105
Vancouver
Ryser AS. Intraoral Scanning Verse Custom Impression Coping for Implant Crowns. Journal of Dentistry and Oral Epidemiology. 2026. doi:10.54289/jdoe2600105
BibTeX
@article{Ryser2026,
author = {Ryser, Andrew S},
title = {Intraoral Scanning Verse Custom Impression Coping for Implant Crowns},
journal = {Journal of Dentistry and Oral Epidemiology},
year = {2026},
doi = {10.54289/jdoe2600105}
}
EUVIMED