Background

Assessment of fluid responsiveness is crucial for optimizing hemodynamic management in critically ill patients. Conventional tests such as the passive leg-raising (PLR) maneuver or fluid challenge may be limited by equipment constraints. This study evaluated the ability of the passive head-up tilt (HUT) test to predict fluid responsiveness without external fluid loading or heart–lung interaction.

Method

This prospective observational study enrolled 52 critically ill adults with shock undergoing cardiac output monitoring using pulse contour analysis. Hemodynamic parameters, including systolic blood pressure (SBP), diastolic blood pressure (DBP), heart rate (HR), stroke volume (SV), and cardiac output (CO), were recorded at baseline, during a 45° head-up tilt, and after returning to the supine position. A standard fluid challenge (250 mL crystalloid or colloid over 15 minutes) was used as the reference, and fluid responsiveness was defined as a stroke volume increase of more than 10%. Diagnostic performance was analyzed using the area under the receiver operating characteristic (AUROC) curve.

Result

Seventeen patients (32.7%) were responders. Most patients were in normal sinus rhythm (86.5%) and under positive-pressure ventilation (82.7%), with no between-group difference. The mean baseline CO was 4.8 L/min (IQR 3.75–6.4), and the mean SBP was 119.5 ± 17.6 mmHg. The change in SV from baseline to 1 minute after HUT showed the best diagnostic accuracy, with an AUROC = 0.67, sensitivity = 76%, and specificity = 57% at a 10% cutoff. Both SV and CO decreased during head elevation and increased after returning to supine, consistent with physiologic changes in venous return.

Conclusion

The passive head-up tilt test demonstrated poor to moderate accuracy for predicting fluid responsiveness. Rather than serving as a replacement for passive leg raising, HUT may be considered a supplementary or screening maneuver in situations where PLR is not feasible because of bed design or patient-related limitations.

Trial registration

TCTR20250129003

Zitieren

APA

Anchalee, S., Thertchanakun, S., Pisitsak, C., & Chuchatwannakul, R. (2026). Passive head-up tilt for predicting fluid responsiveness in critically ill patients. Clinical Critical Care, 34, e260016. https://doi.org/10.54205/ccc.v34.279538

Vancouver

Anchalee S, Thertchanakun S, Pisitsak C, Chuchatwannakul R. Passive head-up tilt for predicting fluid responsiveness in critically ill patients. Clinical Critical Care. 2026;34:e260016. doi:10.54205/ccc.v34.279538

BibTeX
@article{Anchalee2026,
  author = {Anchalee, Santi and Thertchanakun, Sahawat and Pisitsak, Chawika and Chuchatwannakul, Ratima},
  title = {Passive head-up tilt for predicting fluid responsiveness in critically ill patients},
  journal = {Clinical Critical Care},
  year = {2026},
  volume = {34},
  pages = {e260016},
  doi = {10.54205/ccc.v34.279538}
}
Kostenlos starten →