EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Comparison of mean systemic pressure in patients with acute circulatory failure receiving passive leg raising vs. pneumatic leg compression

Panu Boontoterm, Pusit Fuengfoo, Petch Wacharasint

Clinical Critical Care · 2021

DOI: 10.54205//ccc.v29i.252074 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical Critical Care, 2021. Verfasst von Panu Boontoterm und 2 weiteren Autor:innen. Die Arbeit nennt 11 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Driving pressure of venous return (VR) is determined by a pressure gradient between mean systemic pressure (Pms) and central venous pressure (CVP). While passive leg raising (PLR) and pneumatic leg compression PC (PC) can increase VR, no study has explored the effects of these two procedures on Pms and VR-related hemodynamic variables.

Methods

Forty patients with acute circulatory failure were enrolled in this analysis. All patients obtained both PLR and PC, and were measured for Pms, CVP, mean arterial pressure (MAP), cardiac output (CO), VR resistance (RVR), and systemic vascular resistance (SVR) at baseline and immediately after procedures. To minimize carry over effect, the patients were divided in 2 groups based on procedure sequence which were 1) patients receiving PLR first then PC (PLR-first), and 2) patients receiving PC first then PLR (PC-first). Both groups waited for a washout period before performing the 2 second procedure. Primary outcome was difference in Pms between PLR and PC procedures. Secondary outcome were differences in CVP, MAP, CO, RVR, and SVR between PLR and PC procedures.

Results

No difference was found in baseline characteristics and no carry over effect was observed between the 2 groups of patients. Compared with baseline, both PLR and PC significantly increased Pms, CVP, MAP, and CO. PLR increased Pms (9.0±2.3 vs 4.8±1.7 mmHg, p

Zitieren

APA

Boontoterm, P., Fuengfoo, P., & Wacharasint, P. (2021). Comparison of mean systemic pressure in patients with acute circulatory failure receiving passive leg raising vs. pneumatic leg compression. Clinical Critical Care. https://doi.org/10.54205//ccc.v29i.252074

Vancouver

Boontoterm P, Fuengfoo P, Wacharasint P. Comparison of mean systemic pressure in patients with acute circulatory failure receiving passive leg raising vs. pneumatic leg compression. Clinical Critical Care. 2021. doi:10.54205//ccc.v29i.252074

BibTeX
@article{Boontoterm2021,
  author = {Boontoterm, Panu and Fuengfoo, Pusit and Wacharasint, Petch},
  title = {Comparison of mean systemic pressure in patients with acute circulatory failure receiving passive leg raising vs. pneumatic leg compression},
  journal = {Clinical Critical Care},
  year = {2021},
  doi = {10.54205//ccc.v29i.252074}
}
Kostenlos starten →