Fachartikel in der Zeitschrift Al-Rafidain Journal of Medical Sciences ( ISSN 2789-3219 ), online erschienen am 16.04.2025. Verfasst von Noor Ali Alhamdani und 2 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-SA 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Artificial intelligence (AI) has invaded radiographic analysis in a massive way. Besides saving time and effort during decision-making and treatment planning, AI-assisted cephalometric analysis must be reliable, reproducible, accurate, and user-friendly.

Objective

To assess fully AI-driven cephalometric analysis.

Methods

47 lateral cephalometric radiographs were used for comparing the accuracy of AI-operated and manually operated skeletal and dental cephalometric analysis. Both dental and skeletal analyses were digitally performed using web-based platforms (WebCephTM, Cephio, and Ceppro DDH Inc., Korea). SPSS was used for statistical analysis with paired t-test and intra-class correlation.

Results

There were statistical differences between AI landmarking and manual landmarking regarding SNA, ANB, FH to AB, U1 to FH, U1 to SN, U1 to UOP, interincisal angle, U1 to NA (mm), and U1 to NA (deg). The intraclass correlation coefficient (ICC) data showed that the two sets of measurements were very consistent for most readings.

Conclusions

Even though AI provides strong reliability and agreement between methods, the significant difference indicates that AI-operated and manually operated cephalometric analysis may not be interchangeable despite their consistency. AI-based analyses primarily function as assistant tools, and orthodontists need to make judgments or adjustments before making decisions.

Zitieren

APA

Alhamdani, N. A., Khoshnaw, B. M., & Omer, Z. Q. (2025). Assessing the Accuracy and Reliability of Fully AI-Driven Cephalometric Analysis in Comparison to Digital Manual Methods. Al-Rafidain Journal of Medical Sciences ( ISSN 2789-3219 ), 8(2), 71-75. https://doi.org/10.54133/ajms.v8i2.1839

Vancouver

Alhamdani NA, Khoshnaw BM, Omer ZQ. Assessing the Accuracy and Reliability of Fully AI-Driven Cephalometric Analysis in Comparison to Digital Manual Methods. Al-Rafidain Journal of Medical Sciences ( ISSN 2789-3219 ). 2025;8(2):71-75. doi:10.54133/ajms.v8i2.1839

BibTeX
@article{Alhamdani2025,
  author = {Alhamdani, Noor Ali and Khoshnaw, Brwa Mahdi and Omer, Zana Qadir},
  title = {Assessing the Accuracy and Reliability of Fully AI-Driven Cephalometric Analysis in Comparison to Digital Manual Methods},
  journal = {Al-Rafidain Journal of Medical Sciences ( ISSN 2789-3219 )},
  year = {2025},
  volume = {8},
  number = {2},
  pages = {71--75},
  doi = {10.54133/ajms.v8i2.1839}
}
Kostenlos starten →