Flow-Rate-Dependent Thermal Performance of a Counter-Flow Double-Pipe Heat Exchanger: Energy-Balance Assessment, Effectiveness Analysis and Statistical Mapping
IPS Journal of Physical Sciences · 14.11.2026 · 3 (2) · 302-308
DOI: 10.54117/ijps.v3i2.47 ↗Kurz gefasst
Fachartikel in der Zeitschrift IPS Journal of Physical Sciences, online erschienen am 14.11.2026. Verfasst von Lucky Olatunde Odejimi und 2 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
This study presents an experimental multi-variable performance mapping of a water-to-water counter-flow double-pipe heat exchanger conducted in the Thermo Laboratory of the Department of Mechanical Engineering, Igbinedion University Okada. Twenty steady-state operating conditions were examined in which hot-water flow rate ranged from 1.52 to 4.43 L min⁻¹ and cold-water flow rate from 3.12 to 7.02 L min⁻¹. The exchanger comprises a copper inner tube (outer diameter 25.4 mm), effective length 1.50 m and heat-transfer area 0.120 m² based on the outer surface of the inner tube. Measured heat-transfer rates increased from approximately 1.55 kW to 9.40 kW. The overall heat-transfer coefficient rose from 440 to 5144 W m⁻² K⁻¹ while the logarithmic mean temperature difference declined from 29.3 °C to 15.2 °C. Thermal effectiveness increased from 36.2 % to 74.7 %. Linear regression analyses revealed strong positive associations between hot-water flow rate and both average heat duty (R² = 0.997) and overall heat-transfer coefficient (R² = 0.978). The maximum hot/cold energy-balance discrepancy was 0.65 %. Because both stream flow rates varied simultaneously, the results constitute a multi-variable operating map rather than an isolated single-variable effect study. The work provides a transparent, statistically characterised laboratory baseline that can support teaching, equipment commissioning and preliminary design calculations.
Zitieren
APA
Odejimi, L. O., Okotie, E. A., & Aregbe, O. (2026). Flow-Rate-Dependent Thermal Performance of a Counter-Flow Double-Pipe Heat Exchanger: Energy-Balance Assessment, Effectiveness Analysis and Statistical Mapping. IPS Journal of Physical Sciences, 3(2), 302-308. https://doi.org/10.54117/ijps.v3i2.47
Vancouver
Odejimi LO, Okotie EA, Aregbe O. Flow-Rate-Dependent Thermal Performance of a Counter-Flow Double-Pipe Heat Exchanger: Energy-Balance Assessment, Effectiveness Analysis and Statistical Mapping. IPS Journal of Physical Sciences. 2026;3(2):302-308. doi:10.54117/ijps.v3i2.47
BibTeX
@article{Odejimi2026,
author = {Odejimi, Lucky Olatunde and Okotie, Emeke Achojakimoni and Aregbe, Olorunleke},
title = {Flow-Rate-Dependent Thermal Performance of a Counter-Flow Double-Pipe Heat Exchanger: Energy-Balance Assessment, Effectiveness Analysis and Statistical Mapping},
journal = {IPS Journal of Physical Sciences},
year = {2026},
volume = {3},
number = {2},
pages = {302--308},
doi = {10.54117/ijps.v3i2.47}
}