EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Application of HVSR Technique to Characterize the Site Effect at the Seismological Stations in South Africa

E. O. Onyebueke, R. J. Durrheim, M. S. D. Manzi, A. Raveloson, O. A. Ben-Owope, E. O. Iloh

IPS Journal of Engineering and Technology · 18.06.2026 · 2 (1) · 216-235

DOI: 10.54117/a1jazq36 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IPS Journal of Engineering and Technology, online erschienen am 18.06.2026. Verfasst von E. O. Onyebueke und 5 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The use of seismic noise for site response characteristics is now a widely accepted geophysical tool in microzonation and seismic hazard assessment. This study presents the assessment and stability analysis of the site effect characteristics of seismic network stations in South Africa using the horizontal to vertical spectral ratio (HVSR) of ambient seismic noise records. The aim was to assess the stability and reliability of the HVSR parameters (fundamental frequency (F0) and amplification factor (A0) of the ground motion) of the sites and its application to microzonation of cities in South Africa. The stability of the site response parameters was investigated by considering different time spectrum of the day and seasons using twenty four seismological network stations. The observed results revealed that the fundamental frequency of the top sediment was essentially the same in all the analyzed time windows while the amplification amplitude varied slightly with time. The reliability test followed the specific recommendations prescribed by the SESAME project group. It was discovered that the predominant frequency obtained using the HVSR technique is a reliable estimate of the fundamental frequency of the ground motion. The estimated values of the site effect characteristics were used to calculate the thickness of the sedimentary cover and the vulnerability index of the foundation of the seismological stations. The results reflect the geological characteristics of the sites. Therefore, HVSR technique using microtremor signal was considered a reliable, cheap and easy geophysical technique that can complements other geophysical methods for microzonation and seismic hazard assessment in South Africa.

Zitieren

APA

Onyebueke, E. O., Durrheim, R. J., Manzi, M. S. D., Raveloson, A., Ben-Owope, O. A., & Iloh, E. O. (2026). Application of HVSR Technique to Characterize the Site Effect at the Seismological Stations in South Africa. IPS Journal of Engineering and Technology, 2(1), 216-235. https://doi.org/10.54117/a1jazq36

Vancouver

Onyebueke EO, Durrheim RJ, Manzi MSD, Raveloson A, Ben-Owope OA, Iloh EO. Application of HVSR Technique to Characterize the Site Effect at the Seismological Stations in South Africa. IPS Journal of Engineering and Technology. 2026;2(1):216-235. doi:10.54117/a1jazq36

BibTeX
@article{Onyebueke2026,
  author = {Onyebueke, E. O. and Durrheim, R. J. and Manzi, M. S. D. and Raveloson, A. and Ben-Owope, O. A. and Iloh, E. O.},
  title = {Application of HVSR Technique to Characterize the Site Effect at the Seismological Stations in South Africa},
  journal = {IPS Journal of Engineering and Technology},
  year = {2026},
  volume = {2},
  number = {1},
  pages = {216--235},
  doi = {10.54117/a1jazq36}
}
Kostenlos starten →