EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Silicon and Phosphorous cross section Determination and Full energy efficiency calibration of 1273 keV and 1779 keV gamma lines using curve fitting

Anas Muhammad Salisu, Darius Audu Gajere, Sunday A. Jonah

Gadau Journal of Pure and Allied Sciences · 2025

DOI: 10.54117/7ep0r712 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Gadau Journal of Pure and Allied Sciences, 2025. Verfasst von Anas Muhammad Salisu und 2 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The full energy peak efficiency (FEPE) of a detector system is related to the measurement conditions such as the source and detector geometry, and the various detector parameters including detector type (scintillation, solid state), the density and size of the detector material. A full-energy peak contains all the information about a radionuclide therefore, accurate knowledge of FEPE is one of the most important parameters in gamma ray spectrometry practice to identify and quantify gamma activity of any radionuclides. For this reason, the FEPE of 1273keV and 1779keV were determined using the curve fitting approach. In this method the efficiency of standard sources was determined and plotted against energy. A third-degree polynomial equation fitted on the curve at each geometry was used to evaluate the FEPE of the intended gamma line. From our result, at a geometry of 2.20cm, the FEPE of 1273keV and 1779keV compares closely with previous authors and hence, the recommended geometry for analyzing these gamma lines.

Zitieren

APA

Salisu, A. M., Gajere, D. A., & Jonah, S. A. (2025). Silicon and Phosphorous cross section Determination and Full energy efficiency calibration of 1273 keV and 1779 keV gamma lines using curve fitting. Gadau Journal of Pure and Allied Sciences. https://doi.org/10.54117/7ep0r712

Vancouver

Salisu AM, Gajere DA, Jonah SA. Silicon and Phosphorous cross section Determination and Full energy efficiency calibration of 1273 keV and 1779 keV gamma lines using curve fitting. Gadau Journal of Pure and Allied Sciences. 2025. doi:10.54117/7ep0r712

BibTeX
@article{Salisu2025,
  author = {Salisu, Anas Muhammad and Gajere, Darius Audu and Jonah, Sunday A.},
  title = {Silicon and Phosphorous cross section Determination and Full energy efficiency calibration of 1273 keV and 1779 keV gamma lines using curve fitting},
  journal = {Gadau Journal of Pure and Allied Sciences},
  year = {2025},
  doi = {10.54117/7ep0r712}
}
Kostenlos starten →