EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Preliminary evaluation of qualitative RT-PCR and indirect immunofluorescence for SARS-CoV-2 detection in nasopharyngeal swabs samples

Luis G. Medina-Pestana, Nathaly A. Mayora-Hernández, Ivis Luisana-Camejo, Benito Aguilera, Víctor Picos, Elizabeth Ferrer, Daria E. Camacho-García

Microbes, Infection and Chemotherapy · 04.11.2026 · 6 · e2873

DOI: 10.54034/mic.e2873 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Microbes, Infection and Chemotherapy, online erschienen am 04.11.2026. Verfasst von Luis G. Medina-Pestana und 6 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

The COVID-19 pandemic made it essential to expand SARS-CoV-2 diagnostic capacity. Two laboratory techniques—qualitative RT-PCR and indirect immunofluorescence (IIF)—were preliminarily evaluated for virus detection in nasopharyngeal samples.

Methods

RNA extracted from nasopharyngeal swabs of patients with infection confirmed by RT-qPCR was used to establish the amplification conditions for a 128-bp fragment of the SARS-CoV-2 N gene by RT-PCR. Under the selected conditions, 65 samples from patients with clinical manifestations compatible with COVID-19 were analyzed. For IIF, a purified preparation of anti-SARS-CoV-2 IgG antibodies obtained from positive serum samples previously analyzed with a commercial ELISA was used. The antibodies bound to viral antigens in cells from nasopharyngeal swabs and were detected with a fluorescein isothiocyanate-conjugated anti-human IgG antibody.

Results

The selected conditions for amplification of the 128-bp fragment were 1.5 mM MgCl₂, 0.6 µM of each primer, 0.2 mM dNTPs, 5.0 U of Taq polymerase and 5.0 U of reverse transcriptase, and an annealing temperature of 57 °C. Under these conditions, 64 of 65 samples (98.46%) yielded the expected amplicon. IIF revealed fluorescence-positive cells and showed no reactivity against the evaluated panel of other viruses.

Conclusion

Qualitative RT-PCR and IIF showed favorable preliminary results for SARS-CoV-2 detection in nasopharyngeal samples. A complete analytical and clinical evaluation is required before either technique can be considered for diagnostic use.

Zitieren

APA

Medina-Pestana, L. G., Mayora-Hernández, N. A., Luisana-Camejo, I., Aguilera, B., Picos, V., Ferrer, E., & Camacho-García, D. E. (2026). Preliminary evaluation of qualitative RT-PCR and indirect immunofluorescence for SARS-CoV-2 detection in nasopharyngeal swabs samples. Microbes, Infection and Chemotherapy, 6, e2873. https://doi.org/10.54034/mic.e2873

Vancouver

Medina-Pestana LG, Mayora-Hernández NA, Luisana-Camejo I, Aguilera B, Picos V, Ferrer E, et al. Preliminary evaluation of qualitative RT-PCR and indirect immunofluorescence for SARS-CoV-2 detection in nasopharyngeal swabs samples. Microbes, Infection and Chemotherapy. 2026;6:e2873. doi:10.54034/mic.e2873

BibTeX
@article{MedinaPestana2026,
  author = {Medina-Pestana, Luis G. and Mayora-Hernández, Nathaly A. and Luisana-Camejo, Ivis and Aguilera, Benito and Picos, Víctor and Ferrer, Elizabeth and Camacho-García, Daria E.},
  title = {Preliminary evaluation of qualitative RT-PCR and indirect immunofluorescence for SARS-CoV-2 detection in nasopharyngeal swabs samples},
  journal = {Microbes, Infection and Chemotherapy},
  year = {2026},
  volume = {6},
  pages = {e2873},
  doi = {10.54034/mic.e2873}
}
Kostenlos starten →