EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Residential Unit Design for Natural Ventilation in Tropical Multi-Family High-Rises With a Double-Loaded Corridor

Chalermwat Tantasavasdi, Natthaumporn Inprom

Nakhara : Journal of Environmental Design and Planning · 23.11.2023 · 22 (3) · 315

DOI: 10.54028/nj202322315 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Nakhara : Journal of Environmental Design and Planning, online erschienen am 23.11.2023. Verfasst von Chalermwat Tantasavasdi und 1 weiteren Autor:innen. Die Arbeit wurde bisher 5-mal zitiert (Crossref). Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This research investigates practical methods to improve the efficiency of natural ventilation in residential units of multi-family high-rises without additional areas. Typical studio- and one-bedroom-types of small units were redesigned using: 1) air post, 2) transom window, 3) buffer space with one corridor opening and 4) buffer space with two corridor openings. The simulation study using a CFD program to reveal that the indoor average air velocity coefficient (Cv ) in the best redesigned case (0.46) significantly improves from the base case (0.01). The paper demonstrates an example of application to an actual climate in Bangkok, Thailand. It was found that the proposed redesign using buffer spaces can considerably help upgrade the living conditions of the occupants in terms of both thermal comfort (24 hours vs. 0 hours in the comfort zone per day) and indoor air quality (24 hours vs. 8–17 hours that pass the minimum ventilation requirement per day) in the transitional month of February.

Zitieren

APA

Tantasavasdi, C., & Inprom, N. (2023). Residential Unit Design for Natural Ventilation in Tropical Multi-Family High-Rises With a Double-Loaded Corridor. Nakhara : Journal of Environmental Design and Planning, 22(3), 315. https://doi.org/10.54028/nj202322315

Vancouver

Tantasavasdi C, Inprom N. Residential Unit Design for Natural Ventilation in Tropical Multi-Family High-Rises With a Double-Loaded Corridor. Nakhara : Journal of Environmental Design and Planning. 2023;22(3):315. doi:10.54028/nj202322315

BibTeX
@article{Tantasavasdi2023,
  author = {Tantasavasdi, Chalermwat and Inprom, Natthaumporn},
  title = {Residential Unit Design for Natural Ventilation in Tropical Multi-Family High-Rises With a Double-Loaded Corridor},
  journal = {Nakhara : Journal of Environmental Design and Planning},
  year = {2023},
  volume = {22},
  number = {3},
  pages = {315},
  doi = {10.54028/nj202322315}
}
Kostenlos starten →