The Effects of QuikClot Combat Gauze, Fluid Resuscitation, and Movement on Hemorrhage Control in a Porcine Model
ISRN Emergency Medicine · 29.11.2012 · 2012 · 1-6
DOI: 10.5402/2012/927678 ↗Kurz gefasst
Fachartikel in der Zeitschrift ISRN Emergency Medicine, erschienen am 29.11.2012. Verfasst von Don Johnson und 7 weiteren Autor:innen. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 3.0).
Themen: Reanimation
Abstract (Originalsprache)
The purpose of this study was to compare the effectiveness of QuikClot Combat Gauze (QCG) compared to a control group on hemorrhage control; the amount of crystalloid volume infusion on rebleeding; the effect of movement on hemorrhage. This was a prospective, experimental design. Swine were randomly assigned to either the QCG () or the control group (). Investigators transected the femoral artery and vein in each swine. After one minute of uncontrolled hemorrhage, the hemostatic agent, QCG, was placed into the wound followed by standard wound packing. The control group underwent the same procedures but without a hemostatic agent. After five minutes of direct pressure, a standard pressure dressing was applied. After 30 minutes, dressings were removed, and the wound was observed for rebleeding for 5 minutes. If hemostasis occurred, 5 liters of crystalloid was given over 5 minutes, and the wound was observed for rebleeding for 5 additional minutes. If no bleeding occurred, the extremity on the side of the injury was moved. There were significant differences in the amount of hemorrhage (), the amount of fluid administration (), and the number of movements () between the QCG and control.
Zitieren
APA
Johnson, D., Gegel, B., Burgert, J., Gasko, J., Cromwell, C., Jaskowska, M., Steward, R., & Taylor, A. (2012). The Effects of QuikClot Combat Gauze, Fluid Resuscitation, and Movement on Hemorrhage Control in a Porcine Model. ISRN Emergency Medicine, 2012, 1-6. https://doi.org/10.5402/2012/927678
Vancouver
Johnson D, Gegel B, Burgert J, Gasko J, Cromwell C, Jaskowska M, et al. The Effects of QuikClot Combat Gauze, Fluid Resuscitation, and Movement on Hemorrhage Control in a Porcine Model. ISRN Emergency Medicine. 2012;2012:1-6. doi:10.5402/2012/927678
BibTeX
@article{Johnson2012,
author = {Johnson, Don and Gegel, Brian and Burgert, James and Gasko, John and Cromwell, Carrie and Jaskowska, Monika and Steward, Rachel and Taylor, Alexis},
title = {The Effects of QuikClot Combat Gauze, Fluid Resuscitation, and Movement on Hemorrhage Control in a Porcine Model},
journal = {ISRN Emergency Medicine},
year = {2012},
volume = {2012},
pages = {1--6},
doi = {10.5402/2012/927678}
}
EUVIMED