EUVIMEDEUVIMED entdecken
Open Access · CC BY 3.0

Lead Contamination of Surgical Gloves by Contact with a Lead Hand

A Mehra, D E Deakin, A Khan, T M T Sheehan, P Nightingale, S C Deshmukh

ISRN Orthopedics · 2011

DOI: 10.5402/2011/946370 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ISRN Orthopedics, 2011. Verfasst von A Mehra und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics and Clinical Biochemistry, City Hospital, Birmingham B18 7QH, UK. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 7 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 3.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background . “Lead hands” are frequently used to maintain hand and finger position in hand surgery. The malleability and strength of lead make it ideal for this purpose. The aim of this study was to determine the amount of lead transferred to a surgeon's glove during handling of a lead hand.

Method

Sterile surgical gloves were wiped over the surface of a lead hand. The number of wipes was varied, the gloves were then sent to a trace elements laboratory, and the lead content transferred to each glove was determined.

Results

The amount of lead transferred to each glove increased with increasing exposure to the lead hand. After twenty wipes, up to 2 mg of lead was transferred to the surgeon's glove. Covering the lead hand with a sterile drape markedly reduced the lead transferred to the surgeon's glove.

Conclusion

Significant amount of lead is transferred on to the gloves after handling a lead hand. This risks wound contamination and a foreign body reaction. Covering the lead hand with a sterile drape may minimise the risk of surgical wound contamination.

Autor:innen und Institutionen

  • Department of Orthopaedics and Clinical Biochemistry, City Hospital, Birmingham B18 7QH, UK.

Zitieren

APA

Mehra, A., Deakin, D. E., Khan, A., Sheehan, T. M., Nightingale, P., & Deshmukh, S. C. (2011). Lead Contamination of Surgical Gloves by Contact with a Lead Hand. ISRN Orthopedics. https://doi.org/10.5402/2011/946370

Vancouver

Mehra A, Deakin DE, Khan A, Sheehan TM, Nightingale P, Deshmukh SC. Lead Contamination of Surgical Gloves by Contact with a Lead Hand. ISRN Orthopedics. 2011. doi:10.5402/2011/946370

BibTeX
@article{Mehra2011,
  author = {Mehra, A and Deakin, D E and Khan, A and Sheehan, T M T and Nightingale, P and Deshmukh, S C},
  title = {Lead Contamination of Surgical Gloves by Contact with a Lead Hand},
  journal = {ISRN Orthopedics},
  year = {2011},
  doi = {10.5402/2011/946370}
}
Kostenlos starten →