Patient Compliance during 24-Hour Dual pH Probe Monitoring for Extraesophageal Reflux
ISRN Otolaryngology · 2011
DOI: 10.5402/2011/703936 ↗Kurz gefasst
Fachartikel in der Zeitschrift ISRN Otolaryngology, 2011. Verfasst von Joy Musser und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Communication Sciences and Disorders, University of Cincinnati, P.O. Box 670394, Cincinnati, OH 45267, USA. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 3.0).
Abstract (Originalsprache)
Objective
During ambulatory 24-hour dual pH probe monitoring for suspected extraesophageal reflux (EER), patients are responsible for indicating relevant study events. Study interpretation relies on patient accuracy and compliance to test instructions. This study sought to explore patient compliance during pH probe monitoring and evaluated the utility of a Post-Evaluation Questionnaire as a clinical tool. Participants and Methods . Participants were prospectively studied during 24-hour dual pH probe monitoring. Participants used both a food diary and monitor settings to indicate relevant study events. Following pH testing, participants completed a Post-Evaluation Questionnaire regarding test experiences.
Results
Eighty-two participants completed the study. Means and standard deviations were calculated for individual responses on the Post-Evaluation Questionnaire. Means indicate high participant accuracy for study events, and adherence to typical activities and diet over the testing period. Factor analysis was performed on the Post-Evaluation Questionnaire items and identified two factors: “typical experiences” and “times forgot.” Cronbach's alpha demonstrated acceptable reliability levels for questions related to “typical experiences,” but poor reliability for “times forgot” questions.
Conclusions
Assessment of participant compliance during pH probe testing can quickly and easily be completed through a Post-Evaluation Questionnaire. Participant compliance can be assessed for improved study interpretation.
Autor:innen und Institutionen
- Department of Communication Sciences and Disorders, University of Cincinnati, P.O. Box 670394, Cincinnati, OH 45267, USA.
Zitieren
APA
Musser, J., Kelchner, L., Neils-Strunjas, J., & Montrose, M. (2011). Patient Compliance during 24-Hour Dual pH Probe Monitoring for Extraesophageal Reflux. ISRN Otolaryngology. https://doi.org/10.5402/2011/703936
Vancouver
Musser J, Kelchner L, Neils-Strunjas J, Montrose M. Patient Compliance during 24-Hour Dual pH Probe Monitoring for Extraesophageal Reflux. ISRN Otolaryngology. 2011. doi:10.5402/2011/703936
BibTeX
@article{Musser2011,
author = {Musser, Joy and Kelchner, Lisa and Neils-Strunjas, Jean and Montrose, Marshall},
title = {Patient Compliance during 24-Hour Dual pH Probe Monitoring for Extraesophageal Reflux},
journal = {ISRN Otolaryngology},
year = {2011},
doi = {10.5402/2011/703936}
}
EUVIMED