Accuracy of Single-Step versus 2-Step Double-Mix Impression Technique
ISRN Dentistry · 2011
DOI: 10.5402/2011/341546 ↗Kurz gefasst
Fachartikel in der Zeitschrift ISRN Dentistry, 2011. Verfasst von Eduardo Batista Franco und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Operative Dentistry, Endodontics, and Dental Materials, Bauru School of Dentistry, University of São Paulo, Al. Octávio Pinheiro Brisol…. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 3.0). Gefördert von: Conselho Nacional de Desenvolvimento Científico e Tecnológico.
Abstract (Originalsprache)
Objective
To investigate the accuracy of dies obtained from single-step and 2-step double-mix impressions. Material and Methods . Impressions ( n = 10 ) of a stainless steel die simulating a complete crown preparation were performed using a polyether (Impregum Soft Heavy and Light body) and a vinyl polysiloxane (Perfectim Blue Velvet and Flexi-Velvet) in two consistencies, in one or two (without relief) steps. Accuracy of the stone dies was accessed at a measuring microscope, using a metallic crown with perfect fit to the reference crown preparation. Data were submitted to 2-way ANOVA and Tukey test ( α = 0.05 ).
Results
The single-step technique resulted in slightly larger dies, while the 2-step technique without relief produced significantly smaller dies, when compared to the original stainless steel die. Stone dies obtained from 2-step polyether impressions were significantly smaller when compared to dies obtained from 2-step vinyl polysiloxane impressions (Impregum 2-step: −290.94 ± 71.64 μm; Perfectim 2-step: −201.86 ± 28.58 μm). No significant differences were observed in dies obtained from either polyether or vinyl polysiloxane with the single-step technique (Impregum single-step: 63.52 ± 16.60 μm; Perfectim single-step: 79.40 ± 14.11 μm).
Conclusion
Higher discrepancies were detected for the 2-step impression technique without relief for the investigated materials.
Autor:innen und Institutionen
- Department of Operative Dentistry, Endodontics, and Dental Materials, Bauru School of Dentistry, University of São Paulo, Al. Octávio Pinheiro Brisolla, 9-75 Vila Universitária, 17012-901 Bauru, SP, Brazil.
Förderung
- Conselho Nacional de Desenvolvimento Científico e Tecnológico
Zitieren
APA
Franco, E. B., da Cunha, L. F., Herrera, F. S., & Benetti, A. R. (2011). Accuracy of Single-Step versus 2-Step Double-Mix Impression Technique. ISRN Dentistry. https://doi.org/10.5402/2011/341546
Vancouver
Franco EB, da Cunha LF, Herrera FS, Benetti AR. Accuracy of Single-Step versus 2-Step Double-Mix Impression Technique. ISRN Dentistry. 2011. doi:10.5402/2011/341546
BibTeX
@article{Franco2011,
author = {Franco, Eduardo Batista and da Cunha, Leonardo Fernandes and Herrera, Francyle Simões and Benetti, Ana Raquel},
title = {Accuracy of Single-Step versus 2-Step Double-Mix Impression Technique},
journal = {ISRN Dentistry},
year = {2011},
doi = {10.5402/2011/341546}
}
EUVIMED