PENGARUH PARAMETER CT UNTUK OPTIMISASI DOSIS RADIASI DAN KUALITAS CITRA CT SCAN PADA PEMERIKSAAN KEPALA DAN ABDOMEN DI RS SENTRA MEDIKA CIBINONG
Prosiding Seminar Si-INTAN · 2023
DOI: 10.53862/ssi.v3.092023.003 ↗Kurz gefasst
Fachartikel in der Zeitschrift Prosiding Seminar Si-INTAN, 2023. Verfasst von Habib Syeh Alzufri und 1 weiteren Autor:innen.
Abstract (Originalsprache)
Radiation dose optimization in head and abdomen examinations is an effort to ensure safety and minimize the risks of exposure to CT Scan radiation. Therefore, various efforts are necessary to reduce radiation doses. This study aims to obtain an optimal radiation dose while maintaining image quality. The optimization efforts were carried out by the radiology team at RS Sentra Medika Cibinong using the CT Scan GE OPTIMA 660. The method involved scanning head and abdomen phantoms using optimization factors (Noise Index, Slice Thickness, Pitch, and Rotation Time) and then analyzing the images for noise uniformity, MTF (Modulation Transfer Function), and NPS (Noise Power Spectrum) while recording radiation dose in terms of CTDIvol and DLP. Based on the research data using GE standard Head protocol and respective optimizations, the radiation dose values obtained were CTDIVol = 68 mGy; DLP = 2042 mGy.cm and CTDIVol = 48 mGy; DLP = 1662 mGy.cm. Furthermore, the image quality produced by the GE standard Head protocol and respective optimizations resulted in MTF values of 0.55 (1/mm) and 0.91 (1/mm), noise uniformity of 0.6 HU and 1.6 HU, and NPS deviation of 8.7%. Regarding the Abdomen protocol, using GE standard and respective optimizations, the radiation dose values obtained were CTDIVol = 32 mGy; DLP = 1025 mGy.cm and CTDIVol = 22 mGy; DLP = 955 mGy.cm. Additionally, the image quality produced by the GE standard Abdomen protocol and respective optimizations resulted in MTF values of 0.58 (1/mm) and 0.6 (1/mm), noise uniformity of 0.6 HU and 1.6 HU, and NPS deviation of 7.6%. Thus, the protocols using optimization factors were proven to reduce radiation dose by approximately 41.6-45.4% while maintaining image quality compared to the GE standard protocol, which focuses more on improving image quality rather than optimizing the radiation dose received by patients. Keywords: CT Scan, Optimization Factors, Image Quality, CTDIvol, DLP.
Zitieren
APA
Alzufri, H. S., & Nurmiati, D. (2023). PENGARUH PARAMETER CT UNTUK OPTIMISASI DOSIS RADIASI DAN KUALITAS CITRA CT SCAN PADA PEMERIKSAAN KEPALA DAN ABDOMEN DI RS SENTRA MEDIKA CIBINONG. Prosiding Seminar Si-INTAN. https://doi.org/10.53862/ssi.v3.092023.003
Vancouver
Alzufri HS, Nurmiati D. PENGARUH PARAMETER CT UNTUK OPTIMISASI DOSIS RADIASI DAN KUALITAS CITRA CT SCAN PADA PEMERIKSAAN KEPALA DAN ABDOMEN DI RS SENTRA MEDIKA CIBINONG. Prosiding Seminar Si-INTAN. 2023. doi:10.53862/ssi.v3.092023.003
BibTeX
@article{Alzufri2023,
author = {Alzufri, Habib Syeh and Nurmiati, Dede},
title = {PENGARUH PARAMETER CT UNTUK OPTIMISASI DOSIS RADIASI DAN KUALITAS CITRA CT SCAN PADA PEMERIKSAAN KEPALA DAN ABDOMEN DI RS SENTRA MEDIKA CIBINONG},
journal = {Prosiding Seminar Si-INTAN},
year = {2023},
doi = {10.53862/ssi.v3.092023.003}
}
EUVIMED