EUVIMEDEUVIMED entdecken
Crossref

Surface Plasmon Resonance Biosensor in Healthcare Application Using Kretschsmann & Otto Configuration

Nusrat Alim, Mohammad Nasir Uddin

AIUB Journal of Science and Engineering (AJSE) · 31.03.2018 · 17 (1)

DOI: 10.53799/ajse.v17i1.1 ↗

Kurz gefasst

Fachartikel in der Zeitschrift AIUB Journal of Science and Engineering (AJSE), online erschienen am 31.03.2018. Verfasst von Nusrat Alim und 1 weiteren Autor:innen. Die Arbeit wurde bisher 6-mal zitiert (Crossref).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this study, a planar D-shape optical fiber sensor based on Surface Plasmon Resonance phenomenon using two different excitation methods has been demonstrated. The proposed bio-sensor uses Amplitude-Wavelength hybrid detection technique to determine the change in urine refractive index that depends on resonance parameters. The analysis employs finite element method to investigate the optical properties of the proposed sensor. From the results it can be evident that Otto configuration offers greater amount of reflected light intensity dip for a particular urine refractive index in comparison with Kretschmann configuration. For an example, for Otto configuration the dip of reflected light intensity measured in terms of reflectance which attains a value 0.5 for ns (urine refractive index) of 1.489 while Kretschmann configuration provides a dip of 0.65 for the same value of ns. Results also show that the sharpness of reflectance is comparatively higher for the sensor using Otto configuration in comparison with Kretschmann configuration in case of wavelength interrogation. Thus, Otto configuration offers better performance in comparison with Kretschmann configuration.

Zitieren

APA

Alim, N., & Uddin, M. N. (2018). Surface Plasmon Resonance Biosensor in Healthcare Application Using Kretschsmann & Otto Configuration. AIUB Journal of Science and Engineering (AJSE), 17(1). https://doi.org/10.53799/ajse.v17i1.1

Vancouver

Alim N, Uddin MN. Surface Plasmon Resonance Biosensor in Healthcare Application Using Kretschsmann & Otto Configuration. AIUB Journal of Science and Engineering (AJSE). 2018;17(1). doi:10.53799/ajse.v17i1.1

BibTeX
@article{Alim2018,
  author = {Alim, Nusrat and Uddin, Mohammad Nasir},
  title = {Surface Plasmon Resonance Biosensor in Healthcare Application Using Kretschsmann & Otto Configuration},
  journal = {AIUB Journal of Science and Engineering (AJSE)},
  year = {2018},
  volume = {17},
  number = {1},
  doi = {10.53799/ajse.v17i1.1}
}
Kostenlos starten →