EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Surgeon’s Experience and Accuracy of Preoperative Digital Templating in Primary Total Hip Arthroplasty

Maria Surroca iD, Silvia Miguela iD, Agustí Bartra-Ylla iD, Jorge H Nuñez iD, Francesc Angles-Crespo iD

Hip & Pelvis · 01.06.2024 · 36 (2) · 129-134

DOI: 10.5371/hp.2024.36.2.129 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Hip & Pelvis, erschienen am 01.06.2024. Verfasst von Maria Surroca und 4 weiteren Autor:innen. Beteiligte Einrichtung: Hip Unit, Department of Orthopedic Surgery, Fundació Assistencial Mútua Terrassa, Terrassa, Spain. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Preoperative planning has become essential in performance of total hip arthroplasty (THA). However, data regarding the effect of the planner's experience on the accuracy of digital preoperative planning is limited. The objective of this study was to assess the accuracy of digital templating in THA based on the surgeon's experience. Materials and Methods: A retrospective study was conducted. An analysis of 98 anteroposterior pelvic radiographs, which were individually templated by four surgeons (two hip surgeons and two orthopaedic residents) using TraumaCad® digital planning, was performed. A comparison of preoperatively planned sizes with implanted sizes was performed to evaluate the accuracy of predicting component size. The results of preoperative planning performed by hip surgeons and orthopaedic residents were compared for testing of the planner's experience.

Results

Femoral stem was precisely predicted in 32.4% of cases, acetabular component in 40.3%, and femoral offset in 76.7%. Prediction of cup size showed greater accuracy than femoral size among all observers. No differences in any variable were observed among the four groups (acetabular cup P=0.07, femoral stem P=0.82, femoral offset P=0.06). All measurements showed good reliability (intraclass correlation coefficient [ICC] acetabular cup: 0.76, ICC femoral stem: 0.79).

Conclusion

The results of this study might suggest that even though a surgeon's experience supports improved precision during the planning stage, it should not be restricted only to surgeons with a high level of experience. We consider preoperative planning an essential part of the surgery, which should be included in training for orthopaedics residents.

Schlagwörter

Stichwörter der Autor:innen

Data accuracyDimensional measurement accuracyHipPreoperative careTotal hip arthroplasty

Autor:innen und Institutionen

  • Hip Unit, Department of Orthopedic Surgery, Fundació Assistencial Mútua Terrassa, Terrassa, Spain.
  • Department of Surgery, Universitat de Barcelona, Barcelona, Spain.

ORCID-Profile: Maria Surroca, Silvia Miguela, Agustí Bartra-Ylla, Jorge H Nuñez, Francesc Angles-Crespo

Zitieren

APA

Surroca, M., Miguela, S., Bartra-Ylla, A., Nuñez, J. H., & Angles-Crespo, F. (2024). Surgeon’s Experience and Accuracy of Preoperative Digital Templating in Primary Total Hip Arthroplasty. Hip & Pelvis, 36(2), 129-134. https://doi.org/10.5371/hp.2024.36.2.129

Vancouver

Surroca M, Miguela S, Bartra-Ylla A, Nuñez JH, Angles-Crespo F. Surgeon’s Experience and Accuracy of Preoperative Digital Templating in Primary Total Hip Arthroplasty. Hip & Pelvis. 2024;36(2):129-134. doi:10.5371/hp.2024.36.2.129

BibTeX
@article{Surroca2024,
  author = {Surroca, Maria and Miguela, Silvia and Bartra-Ylla, Agustí and Nuñez, Jorge H and Angles-Crespo, Francesc},
  title = {Surgeon’s Experience and Accuracy of Preoperative Digital Templating in Primary Total Hip Arthroplasty},
  journal = {Hip & Pelvis},
  year = {2024},
  volume = {36},
  number = {2},
  pages = {129--134},
  doi = {10.5371/hp.2024.36.2.129}
}