Dislocation after Revision Total Hip Arthroplasty: A Comparison between Dual Mobility and Conventional Total Hip Arthroplasty
Hip & Pelvis · 31.12.2023 · 35 (4) · 233-237
DOI: 10.5371/hp.2023.35.4.233 ↗Kurz gefasst
Fachartikel in der Zeitschrift Hip & Pelvis, online erschienen am 04.12.2023. Verfasst von Hyun Sik Shin und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Hanyang University College of Medicine, Seoul, Korea. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 12 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Themen: Mobilisation
Abstract (Originalsprache)
Purpose
The objective of this study was to analyze the results from a cohort of patients who underwent a revision total hip arthroplasty (THA) using a dual mobility cup (DMC) implant. Materials and Methods: A retrospective review of revised THAs was conducted using the database from a single tertiary referral hospital. A total of 91 revision THAs from 91 patients were included in the study. There were 46 male hips and 45 female hips. The mean age was 56.3±14.6 years, and the mean follow-up period was 6.4±5.9 years. In performance of revision THAs, the DMC implants were used in 18 hips (19.8%), and the conventional implants were used in 73 hips (80.2%).
Results
During the follow-up period, three dislocations were identified, and the overall dislocation rate was 3.3%. Early dislocation (at one month postoperatively) occurred in one patient, while late dislocation (at a mean of 7.5 years) occurred in two patients. There was no occurrence of dislocation in the DMC group (0%), and three dislocations were detected in the conventional group (4.1%). However, no significant difference in the rate of dislocation was observed between the two groups (P=0.891).
Conclusion
Although the rate of dislocation was higher in the conventional group, there were no statistically significant differences between the two groups due to the small number of patients. Nevertheless, we believe that the dual mobility design is advantageous in terms of reducing dislocation rate and can be recommended as an option for a revision THA.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopaedic Surgery, Hanyang University College of Medicine, Seoul, Korea.
ORCID-Profile: Hyun Sik Shin, Dong-Hong Kim, Hyung Seok Kim, Hyung Seob Ahn, Yeesuk Kim
Zitieren
APA
Shin, H. S., Kim, D. H., Kim, H. S., Ahn, H. S., & Kim, Y. (2023). Dislocation after Revision Total Hip Arthroplasty: A Comparison between Dual Mobility and Conventional Total Hip Arthroplasty. Hip & Pelvis, 35(4), 233-237. https://doi.org/10.5371/hp.2023.35.4.233
Vancouver
Shin HS, Kim DH, Kim HS, Ahn HS, Kim Y. Dislocation after Revision Total Hip Arthroplasty: A Comparison between Dual Mobility and Conventional Total Hip Arthroplasty. Hip & Pelvis. 2023;35(4):233-237. doi:10.5371/hp.2023.35.4.233
BibTeX
@article{Shin2023,
author = {Shin, Hyun Sik and Kim, Dong-Hong and Kim, Hyung Seok and Ahn, Hyung Seob and Kim, Yeesuk},
title = {Dislocation after Revision Total Hip Arthroplasty: A Comparison between Dual Mobility and Conventional Total Hip Arthroplasty},
journal = {Hip & Pelvis},
year = {2023},
volume = {35},
number = {4},
pages = {233--237},
doi = {10.5371/hp.2023.35.4.233}
}
EUVIMED