EUVIMEDEUVIMED entdecken
Open Access · CC BY-SA 4.0

Studi Eksperimental Zeolit sebagai Pengganti Sebagian Semen terhadap Kuat Tekan Self-Compacting Concrete (SCC)

A Shakira, E Widyaningsih

Jurnal MESIL (Mesin Elektro Sipil) · 18.11.2026 · 7 (2) · 27-36

DOI: 10.53695/jm.v7i2.1721 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Jurnal MESIL (Mesin Elektro Sipil), online erschienen am 18.11.2026. Verfasst von A Shakira und 1 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-SA 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study aims to evaluate the mix design, fresh concrete properties, and compressive strength development of Self-Compacting Concrete (SCC) utilizing natural zeolite as a partial cement replacement. The zeolite substitution ratios were set at 0%, 5%, 10%, 12.5%, and 15% by weight of cement, targeting a specified compressive strength of 45 MPa at 28 days. The mix proportions were developed based on SNI 03-6468-2000 in conjunction with Okamura's method and Bina Marga SKh.1.7.23 specifications. Slump flow tests were conducted to determine fresh workability, while compressive strength tests on 10x20 cm cylindrical specimens were performed at ages of 7, 14, and 28 days. The results revealed that increasing zeolite content reduced slump flow due to the higher water absorption and specific surface area of zeolite particles. The mixtures with 0%, 5%, and 10% zeolite achieved slump flow values of 60 cm, 58 cm, and 58 cm, respectively, complying with the EFNARC Class SF1 criteria. Conversely, the 12.5% and 15% mixtures failed to meet the flowability thresholds. Regarding hardened properties, the 10% zeolite replacement yielded optimum mechanical performance, achieving a 28-day compressive strength of 42.43 MPa (a 4.05% increase compared to the 40.78 MPa control). Exceeding 10% zeolite replacement caused strength degradation due to the reduction of primary cementitious binder. Fracture behavior evaluation confirmed normal failure modes (cone, cone and split, cone and shear) across all test specimens. In conclusion, a 10% zeolite replacement ratio is identified as the optimum dosage that balances optimal workability and compressive strength in SCC.

Zitieren

APA

Shakira, A., & Widyaningsih, E. (2026). Studi Eksperimental Zeolit sebagai Pengganti Sebagian Semen terhadap Kuat Tekan Self-Compacting Concrete (SCC). Jurnal MESIL (Mesin Elektro Sipil), 7(2), 27-36. https://doi.org/10.53695/jm.v7i2.1721

Vancouver

Shakira A, Widyaningsih E. Studi Eksperimental Zeolit sebagai Pengganti Sebagian Semen terhadap Kuat Tekan Self-Compacting Concrete (SCC). Jurnal MESIL (Mesin Elektro Sipil). 2026;7(2):27-36. doi:10.53695/jm.v7i2.1721

BibTeX
@article{Shakira2026,
  author = {Shakira, A and Widyaningsih, E},
  title = {Studi Eksperimental Zeolit sebagai Pengganti Sebagian Semen terhadap Kuat Tekan Self-Compacting Concrete (SCC)},
  journal = {Jurnal MESIL (Mesin Elektro Sipil)},
  year = {2026},
  volume = {7},
  number = {2},
  pages = {27--36},
  doi = {10.53695/jm.v7i2.1721}
}