EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

High-Damping Rubber Bearing Base-Isolation Performance under Different Seismic Hazard Levels

Indra Ariani, Fachriza Noor Abdi, Muhammad Jazir A Lkas, Masayu Widiastuti, Budi Haryanto, Heri Sutanto, Triana Sharly P. Arifin, Citra Anggita, Chalsi Mala Sari, Moch. Gaharu D. Devedo, Dharwati P. Sari

Civil and Sustainable Urban Engineering · 25.10.2026 · 6 (2)

DOI: 10.53623/csue.v6i2.1436 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Civil and Sustainable Urban Engineering, online erschienen am 25.10.2026. Verfasst von Indra Ariani und 10 weiteren Autor:innen. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Base isolation can reduce seismic forces transmitted to building superstructures, but its effectiveness depends on seismic hazard conditions, bearing properties, and structural response. This study compares the reported seismic responses of a reinforced-concrete hospital building with fixed-base and high-damping rubber bearing (HDRB) configurations under three Indonesian seismic hazard scenarios: Samarinda, Aceh, and Palu. Six analytical cases were evaluated using identical reported building geometries. The assessment considered base shear, floor displacement, interstory drift, and P–Delta stability. The reported base shear decreased from 4,902 to 3,754 kN in Samarinda, from 16,371 to 10,914 kN in Aceh, and from 16,997 to 11,331 kN in Palu, corresponding to reductions of 23.42%, 33.33%, and 33.34%, respectively. The isolated models generally exhibited greater absolute floor displacements than the fixed-base models. However, inconsistencies between the reported floor-displacement and interstory-drift values prevent a definitive assessment of drift compliance. Furthermore, the available information is insufficient to independently verify the HDRB constitutive model or determine story-level P–Delta stability coefficients. Although the results demonstrate reduced base shear across all three HDRB configurations, these reductions alone do not establish full compliance with seismic design codes or ensure the hospital's operational continuity following an earthquake. Further verification of site-specific seismic spectra, bearing properties, isolation displacement capacity, interstory drift, and second-order effects is necessary before the findings can support final engineering design decisions.

Zitieren

APA

Ariani, I., Abdi, F. N., Lkas, M. J. A., Widiastuti, M., Haryanto, B., Sutanto, H., Arifin, T. S. P., Anggita, C., Sari, C. M., Devedo, M. G. D., & Sari, D. P. (2026). High-Damping Rubber Bearing Base-Isolation Performance under Different Seismic Hazard Levels. Civil and Sustainable Urban Engineering, 6(2). https://doi.org/10.53623/csue.v6i2.1436

Vancouver

Ariani I, Abdi FN, Lkas MJA, Widiastuti M, Haryanto B, Sutanto H, et al. High-Damping Rubber Bearing Base-Isolation Performance under Different Seismic Hazard Levels. Civil and Sustainable Urban Engineering. 2026;6(2). doi:10.53623/csue.v6i2.1436

BibTeX
@article{Ariani2026,
  author = {Ariani, Indra and Abdi, Fachriza Noor and Lkas, Muhammad Jazir A and Widiastuti, Masayu and Haryanto, Budi and Sutanto, Heri and Arifin, Triana Sharly P. and Anggita, Citra and Sari, Chalsi Mala and Devedo, Moch. Gaharu D. and Sari, Dharwati P.},
  title = {High-Damping Rubber Bearing Base-Isolation Performance under Different Seismic Hazard Levels},
  journal = {Civil and Sustainable Urban Engineering},
  year = {2026},
  volume = {6},
  number = {2},
  doi = {10.53623/csue.v6i2.1436}
}
Kostenlos starten →