POLIMERY WDRUKOWANE MOLEKULARNIE W CZUJNIKACH CHEMICZNYCH ELEKTROCHEMICZNIE ROZPOZNAJĄCYCH WYBRANE SUBSTANCJE TOKSYCZNE ZA POMOCĄ 'EFEKTU BRAMKI
Wiadomości Chemiczne · 2026 · 3-4 · 715-757
DOI: 10.53584/wiadchem.2026.04.4 ↗Kurz gefasst
Fachartikel in der Zeitschrift Wiadomości Chemiczne, 2026. Verfasst von Patrycja Lach und 2 weiteren Autor:innen.
Abstract (Originalsprache)
Developing fast, reliable, and cost-effective analytical methods for detecting toxic substances in food and dietary supplements remains a significant challenge. This article summarizes the design and validation of chemical sensors based on molecularly imprinted polymers (MIPs), which mainly operate through the so-called "gate effect". In the first part, electrochemical chemosensors selective toward N-nitroso-L-proline (Pro-NO), a food contaminant, and p-synephrine (SYN), a dietary supplement constituent, were developed. Functional monomers were preselected using density functional theory (DFT), and conducting MIP films were deposited via electropolymerization. Complete template removal and polymer characterization were confirmed using electrochemical (differential pulse voltammetry, DPV, and electrochemical impedance spectroscopy, EIS), spectroscopic (X-ray photoelectron spectroscopy, XPS, and polarization-modulation infrared reflection-absorption spectroscopy, PM-IRRAS), and microscopic (atomic force microscopy, AFM) techniques. The resulting sensors exhibited high selectivity and nanomolar detection limits, enabling the successful determination of analytes in real food samples. The second part investigated the gate effect mechanism using a SYN-MIP model system. It was shown that the signal decrease was not caused by swelling/shrinking of the MIP layer but by reduced polymer conductivity upon analyte binding. Based on these findings, a novel self-reporting electrochemical sensor with a covalently immobilized ferrocene redox probe was designed. This system exhibited improved analytical performance compared to traditional gate-effect sensors. Finally, self-reporting sensors for glyphosate (GLY) detection were devised. Electroactive MIP nanoparticles with an integrated redox probe were synthesized via solid-phase synthesis and immobilized on electrode surfaces. These sensors achieved extremely low limits of detection and enabled reliable GLY determination in river water samples. The results presented highlight the high potential of MIP-based chemical sensors for the selective detection of food and dietary supplement toxins, as well as for environmental monitoring. These results contributed to the Ph.D. thesis of the corresponding author. Keywords:
Zitieren
APA
Lach, P., Cieplak, M., & Kutner, W. (2026). POLIMERY WDRUKOWANE MOLEKULARNIE W CZUJNIKACH CHEMICZNYCH ELEKTROCHEMICZNIE ROZPOZNAJĄCYCH WYBRANE SUBSTANCJE TOKSYCZNE ZA POMOCĄ 'EFEKTU BRAMKI. Wiadomości Chemiczne, 3-4, 715-757. https://doi.org/10.53584/wiadchem.2026.04.4
Vancouver
Lach P, Cieplak M, Kutner W. POLIMERY WDRUKOWANE MOLEKULARNIE W CZUJNIKACH CHEMICZNYCH ELEKTROCHEMICZNIE ROZPOZNAJĄCYCH WYBRANE SUBSTANCJE TOKSYCZNE ZA POMOCĄ 'EFEKTU BRAMKI. Wiadomości Chemiczne. 2026;3-4:715-757. doi:10.53584/wiadchem.2026.04.4
BibTeX
@article{Lach2026,
author = {Lach, Patrycja and Cieplak, Maciej and Kutner, Włodzimierz},
title = {POLIMERY WDRUKOWANE MOLEKULARNIE W CZUJNIKACH CHEMICZNYCH ELEKTROCHEMICZNIE ROZPOZNAJĄCYCH WYBRANE SUBSTANCJE TOKSYCZNE ZA POMOCĄ 'EFEKTU BRAMKI},
journal = {Wiadomości Chemiczne},
year = {2026},
volume = {3-4},
pages = {715--757},
doi = {10.53584/wiadchem.2026.04.4}
}
EUVIMED