EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Palm Cooling Between Sets Reduces Perceived Exertion Without Enhancing Performance During High-Load Deadlifts

Jeff Buxton, Jonny Aloi, Ryan Hersey, Hunter Presgrave, Stewart McClain, Nico Flati, Hayden Gerhart, Philip Prins

Research in Strength and Performance · 27.10.2025 · 5 (1)

DOI: 10.53520/rdsp2025.105161 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Research in Strength and Performance, online erschienen am 27.10.2025. Verfasst von Jeff Buxton und 7 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref). Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

This study investigated the effects of inter-set palm cooling on performance, physiological, and perceptual responses during high-load deadlift exercise.

Methods

Twelve resistance-trained males (age: 20.6 ± 1.4 years) completed two randomized, counterbalanced experimental sessions involving repeated sets of hex bar deadlifts at 95% of their estimated 5-RM. During rest intervals, participants either sat passively without a device (no palm cooling; NPC) or held a commercially available palm cooling device (palm cooling; PC). Performance metrics (total volume, bar velocity, power, and force), physiological responses (heart rate, core and skin temperature), and perceptual measures (RPE, affect, thermal comfort, and perceived recovery) were recorded.

Results

No significant differences were observed between PC and NPC conditions for performance or physiological outcomes (p>0.05). Although not statistically significant, PC resulted in greater total volume (+15%), partial (concentric-phase) power (+4%), and peak force (+5%). Perceptual responses differed significantly, with PC producing lower RPE (p=0.049), higher affect (p=0.049), and improved thermal comfort (p=0.002), but unexpectedly lower perceived recovery between sets (p=0.001).

Conclusions

PC did not significantly enhance performance or physiological recovery during high-load deadlifts but improved perceptual responses, supporting the hypothesis that PC may modulate central sensory feedback during exercise. These findings suggest PC may be especially useful during high-intensity resistance training in hot environments or for athletes sensitive to thermal strain.

Zitieren

APA

Buxton, J., Aloi, J., Hersey, R., Presgrave, H., McClain, S., Flati, N., Gerhart, H., & Prins, P. (2025). Palm Cooling Between Sets Reduces Perceived Exertion Without Enhancing Performance During High-Load Deadlifts. Research in Strength and Performance, 5(1). https://doi.org/10.53520/rdsp2025.105161

Vancouver

Buxton J, Aloi J, Hersey R, Presgrave H, McClain S, Flati N, et al. Palm Cooling Between Sets Reduces Perceived Exertion Without Enhancing Performance During High-Load Deadlifts. Research in Strength and Performance. 2025;5(1). doi:10.53520/rdsp2025.105161

BibTeX
@article{Buxton2025,
  author = {Buxton, Jeff and Aloi, Jonny and Hersey, Ryan and Presgrave, Hunter and McClain, Stewart and Flati, Nico and Gerhart, Hayden and Prins, Philip},
  title = {Palm Cooling Between Sets Reduces Perceived Exertion Without Enhancing Performance During High-Load Deadlifts},
  journal = {Research in Strength and Performance},
  year = {2025},
  volume = {5},
  number = {1},
  doi = {10.53520/rdsp2025.105161}
}
Kostenlos starten →