Latin American experience with blood component’s quality control obtained by buffy coat method
International Journal of Blood Transfusion and Immunohematology · 2020
DOI: 10.5348/100055z02dm2020cr ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Blood Transfusion and Immunohematology, 2020. Verfasst von Dalia María Moreno Cardona und 9 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 10 Literaturangaben.
Abstract (Originalsprache)
Aims
To explore the compliance with European standards for the quality control (QC) parameters of blood components production in Latin American blood banks, evaluating QC data results processed with red blood cell (RBC), and platelet concentrates (PL) produced.
Methods
An observational retrospective cross-sectional study was conducted with data from one year’s production QC data of platelet concentrate (PL) from the buffy-coat (BC) removal method. Red blood cell was collected in three blood banks from Mexico, Colombia, and Chile. Analysis of the quality limits established in each country was made using Pearson’s Chi-square test. Dunnett’s T3 test evaluated the comparative analysis of the mean. All the tests were performed with bilateral contrast, achieving statistical significance when p ≤ 0.05.
Results
The mean of the total results for the RBC evaluated was volume 277 mL ± 21; hematocrit (HCT) 58.7% ± 3.6; leukocytes (×109/mL) 0.47 ± 0.31. Results for PL were volume: 67 ± 10; platelet count (×109/mL): 76.8 ± 24; leukocytes (×109/mL) 0.02 ± 0.02. According to these total results, the compliance with respect to the control performed was for RBC: Volume 97.9%; hematocrit 98.8%; leukocytes 97%. For PL was 100% for volume; platelet count 82.3%; leukocytes 95.3%.
Conclusion
The QC results conclude that the RBC with the BC removal process produces high-quality components, with a reduced concentration of leukocytes, complying with European Union (EU) guidelines and allow to obtain single platelet from BC with high quality.
Zitieren
APA
Cardona, D. M. M., Frontier, L., Álvarez, I., Ibarra, Y., Morales, Y., Alvarado, A., Martínez, K., Cristancho, N., Rolon, M., & Hernández, Z. (2020). Latin American experience with blood component’s quality control obtained by buffy coat method. International Journal of Blood Transfusion and Immunohematology. https://doi.org/10.5348/100055z02dm2020cr
Vancouver
Cardona DMM, Frontier L, Álvarez I, Ibarra Y, Morales Y, Alvarado A, et al. Latin American experience with blood component’s quality control obtained by buffy coat method. International Journal of Blood Transfusion and Immunohematology. 2020. doi:10.5348/100055z02dm2020cr
BibTeX
@article{Cardona2020,
author = {Cardona, Dalia María Moreno and Frontier, Ludwig and Álvarez, Ignacio and Ibarra, Yolanda and Morales, Yazmín and Alvarado, Alicia and Martínez, Karin and Cristancho, Nohora and Rolon, Mary and Hernández, Zuly},
title = {Latin American experience with blood component’s quality control obtained by buffy coat method},
journal = {International Journal of Blood Transfusion and Immunohematology},
year = {2020},
doi = {10.5348/100055z02dm2020cr}
}
EUVIMED