EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Emergency department bedside ultrasonographic assessment of optic nerve sheath diameter to detect raised intracranial pressure in head trauma patients – An observational study

Nikhil Paul, Visakh S. Vinod, M. J. Archu, Keerthana Manoharan K. K., S. M. Linu, Salooja Sulthana

Journal of Emergency Medicine, Trauma & Acute Care · 17.06.2026 · 2026 (2)

DOI: 10.5339/jemtac.2026.25 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Emergency Medicine, Trauma & Acute Care, erschienen am 17.06.2026. Verfasst von Nikhil Paul und 5 weiteren Autor:innen. Die Arbeit nennt 54 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

Traumatic brain injury is a leading cause of death in low- and middle-income countries, including India, often linked to elevated intracranial pressure (ICP). Early detection is essential to prevent secondary damage. Invasive techniques, though accurate, carry risks, while computed tomography (CT) and magnetic resonance imaging (MRI) face accessibility and radiation limitations. This study aimed to evaluate the diagnostic accuracy of bedside ultrasound measurement of the optic nerve sheath diameter (ONSD) for detecting raised ICP (>20 mmHg), using CT as the reference standard.

Methods

A hospital-based observational study was conducted in the Emergency Department of a tertiary care center in India. A total of 252 head trauma patients were included. A linear ultrasound probe was used to measure ONSD, and CT scans were performed. Sensitivity, specificity, and receiver operating characteristic (ROC) analysis were used to assess the diagnostic accuracy of ONSD.

Results

The average ONSD measured 6.7 mm (SD ± 1.8), and 66% of patients demonstrated values exceeding 5 mm. A threshold of ≥5.8 mm provided optimal diagnostic performance, yielding 85.5% sensitivity and 87.8% specificity for detecting elevated ICP. ROC analysis showed an area under the curve of 0.919, reflecting excellent diagnostic accuracy. CT findings confirmed raised ICP in 82.5% of patients.

Conclusion

Point-of-care ultrasound measurement of the ONSD is a reliable, noninvasive method for identifying elevated ICP in patients with head injury. Future research should validate its utility across diverse settings.

Zitieren

APA

Paul, N., Vinod, V. S., Archu, M. J., K., K. M. K., Linu, S. M., & Sulthana, S. (2026). Emergency department bedside ultrasonographic assessment of optic nerve sheath diameter to detect raised intracranial pressure in head trauma patients – An observational study. Journal of Emergency Medicine, Trauma & Acute Care, 2026(2). https://doi.org/10.5339/jemtac.2026.25

Vancouver

Paul N, Vinod VS, Archu MJ, K. KMK, Linu SM, Sulthana S. Emergency department bedside ultrasonographic assessment of optic nerve sheath diameter to detect raised intracranial pressure in head trauma patients – An observational study. Journal of Emergency Medicine, Trauma & Acute Care. 2026;2026(2). doi:10.5339/jemtac.2026.25

BibTeX
@article{Paul2026,
  author = {Paul, Nikhil and Vinod, Visakh S. and Archu, M. J. and K., Keerthana Manoharan K. and Linu, S. M. and Sulthana, Salooja},
  title = {Emergency department bedside ultrasonographic assessment of optic nerve sheath diameter to detect raised intracranial pressure in head trauma patients – An observational study},
  journal = {Journal of Emergency Medicine, Trauma & Acute Care},
  year = {2026},
  volume = {2026},
  number = {2},
  doi = {10.5339/jemtac.2026.25}
}
Kostenlos starten →