Diagnostic Accuracy of the Archimedes Spiral Test for Essential Tremor: A Meta-Analysis
Tremor and Other Hyperkinetic Movements · 10.04.2026 · 16 · 25
DOI: 10.5334/tohm.1151 ↗Kurz gefasst
Metaanalyse in der Zeitschrift Tremor and Other Hyperkinetic Movements, online erschienen am 10.04.2026. Verfasst von Victor Fellipe Bispo Macêdo und 2 weiteren Autor:innen. Beteiligte Einrichtung: Universidade Federal de Alagoas, UFAL, Maceió, Alagoas, Brazil. Hauptthemen laut MEDLINE: Essential Tremor. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Fundação de Amparo à Pesquisa do Estado de Alagoas.
Abstract (Originalsprache)
Background
The Archimedes spiral test is widely used in clinical neurology to evaluate tremor, yet its diagnostic performance for essential tremor (ET) remains unclear and methodologically inconsistent across studies.
Objective
To determine the diagnostic accuracy of the Archimedes spiral test for distinguishing ET from healthy controls (HC) and to identify methodological and technological factors associated with improved performance.
Methods
A systematic review and meta-analysis were conducted according to PRISMA 2020 guidelines (PROSPERO: CRD420251167793). Eight studies (1,046 participants) were included. Risk of bias was assessed with QUADAS-2. Pooled diagnostic accuracy was estimated using a random-effects model, and subgroup/meta-regression analyses examined the impact of digital acquisition, AI algorithms, EMG/accelerometry, and execution parameters.
Results
The pooled diagnostic accuracy was 0.89 (95% CI: 0.77–0.95; I² = 75.4%). Technology-assisted methods (digital capture or AI-based analysis) demonstrated higher accuracy (0.91; 95% CI: 0.79–0.96) than manual approaches (0.78; 95% CI: 0.70–0.84), although differences did not reach statistical significance. Exploratory analyses suggested that medication withdrawal, absence of arm support, digital recording, and standardized execution protocols may contribute to improved diagnostic performance.
Conclusions
The Archimedes spiral shows moderate-to-high diagnostic accuracy for ET, particularly when combined with digital acquisition and objective analytic methods. Given the small number of available studies and substantial methodological heterogeneity, these findings should be interpreted as exploratory. Standardized digital protocols may enhance reproducibility and support the development of scalable, clinic-ready tremor biomarkers.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Universidade Federal de Alagoas, UFAL, Maceió, Alagoas, Brazil.
- Hospital Santa Casa de Misericórdia de Maceió, Maceió, Alagoas, Brazil.
ORCID-Profile: Victor Fellipe Bispo Macêdo, Matheus Lang, Jorge Artur Peçanha de Miranda Coelho
Förderung
- Fundação de Amparo à Pesquisa do Estado de Alagoas
Zitieren
APA
Macêdo, V. F. B., Lang, M., & de Miranda Coelho, J. A. P. (2026). Diagnostic Accuracy of the Archimedes Spiral Test for Essential Tremor: A Meta-Analysis. Tremor and Other Hyperkinetic Movements, 16, 25. https://doi.org/10.5334/tohm.1151
Vancouver
Macêdo VFB, Lang M, de Miranda Coelho JAP. Diagnostic Accuracy of the Archimedes Spiral Test for Essential Tremor: A Meta-Analysis. Tremor and Other Hyperkinetic Movements. 2026;16:25. doi:10.5334/tohm.1151
BibTeX
@article{Macdo2026,
author = {Macêdo, Victor Fellipe Bispo and Lang, Matheus and de Miranda Coelho, Jorge Artur Peçanha},
title = {Diagnostic Accuracy of the Archimedes Spiral Test for Essential Tremor: A Meta-Analysis},
journal = {Tremor and Other Hyperkinetic Movements},
year = {2026},
volume = {16},
pages = {25},
doi = {10.5334/tohm.1151}
}
EUVIMED