Abstract (Originalsprache)

Background

Thoracolumbar burst fractures are an important aspect of spinal injuries, which can be treated by surgery to stabilize and restore neurological function. Whether to use short-segment or long-segment posterior pedicle screw fixation is a controversial issue. This study aimed to compare radiological outcomes of short-segment fixation instrumentation versus long-segment fixation of thoracolumbar burst fractures.

Methods

This study was conducted at Department of Orthopaedic Surgery, National Institute of Traumatology and Orthopaedic Rehabilitation (NITOR), Dhaka, Bangladesh from July 2024 to June 2025, involving the recruitment of 91 consecutive patients who sustained a thoracolumbar burst fracture and were treated with posterior pedicle screw fixation. The patients were separated into two groups: short-segment fixation (n = 46) and long-segment fixation (n = 45). The neurological status was assessed on the basis of the ASIA Impairment Scale. Data were entered and analyzed using SPSS version 26.

Results

The two groups had a significant within-group radiological improvement. Fixation with short-segments had a mean Cobb angle correction of 9.31° and kyphotic angle correction of 13.24°. The long-segment fixation attained a correction of 8.31° and 11.20°, respectively. There was no significant difference in Cobb angle correction between groups (P = 0.187), but there was significantly greater kyphotic correction with short-segment fixation (P = 0.022). Nevertheless, the correction loss was much higher in short-segment fixation (6.02° vs 4.69°, P = 0.005). Both groups improved neurologically on the ASIA Impairment Scale.

Conclusion

The two techniques of surgery provide a great radiological outcome in thoracolumbar burst fractures. Short segment Fixation with the index vertebra provides similar Cobb angle correction and better kyphotic reduction, but with higher correction loss. The fixation in the long segment offers superior long-term maintenance of correction.

Zitieren

APA

Shorfuddin, K. M., Motin, M. A., Hasan, M. M., Billah, S. M., Islam, M. M., Ashraf, M. A., Shah, M. A., & Kabir, H. Z. (2026). Radiological Comparison of Short-Segment Fixation with Index Vertebra Instrumentation Versus Long-Segment Fixation in Thoracolumbar Burst Fractures. Annals of International Medical and Dental Research, 12(2), 1-7. https://doi.org/10.53339/aimdr.2026.12.2.1

Vancouver

Shorfuddin KM, Motin MA, Hasan MM, Billah SM, Islam MM, Ashraf MA, et al. Radiological Comparison of Short-Segment Fixation with Index Vertebra Instrumentation Versus Long-Segment Fixation in Thoracolumbar Burst Fractures. Annals of International Medical and Dental Research. 2026;12(2):1-7. doi:10.53339/aimdr.2026.12.2.1

BibTeX
@article{Shorfuddin2026,
  author = {Shorfuddin, K. M. and Motin, Md Abdul and Hasan, Md Mahmudul and Billah, S.M. Masum and Islam, Mohd. Mohidul and Ashraf, Md. Ali and Shah, Md. Ali and Kabir, Hasnan Zobayed},
  title = {Radiological Comparison of Short-Segment Fixation with Index Vertebra Instrumentation Versus Long-Segment Fixation in Thoracolumbar Burst Fractures},
  journal = {Annals of International Medical and Dental Research},
  year = {2026},
  volume = {12},
  number = {2},
  pages = {1--7},
  doi = {10.53339/aimdr.2026.12.2.1}
}
Kostenlos starten →