Effect of controlled hypotensive anesthesia on intraoperative blood loss and surgical field visibility in micro-ear surgery
Annals of International Medical and Dental Research · 2026-02 · 12 (1) · 85-90
DOI: 10.53339/aimdr.2026.12.1.14 ↗Kurz gefasst
Fachartikel in der Zeitschrift Annals of International Medical and Dental Research, 2026-02. Verfasst von Md. Nurullah und 2 weiteren Autor:innen.
Abstract (Originalsprache)
Background
Micro-ear surgery demands an immaculate surgical field, yet conventional anesthesia often leads to capillary ooze that obscures delicate structures. Controlled hypotensive anesthesia (CHA) is a strategy to mitigate this by reducing mean arterial pressure, but its comparative effectiveness in micro-ear surgery requires further validation.
Objective
To compare the effect of CHA versus normotensive anesthesia on intraoperative blood loss and surgical field visibility in patients undergoing micro-ear surgery.
Methods
A case-control study was conducted at Ibn Sina Medical College and Hospital, Dhaka, Bangladesh, from January 2023 to December 2024. A total of 80 patients were selected via purposive sampling: 40 cases received CHA, and 40 controls received standard normotensive anesthesia. Intraoperative blood loss was measured volumetrically. Surgical field visibility was assessed by the blinded primary surgeon using the 6-point scale at regular intervals. Data were analyzed using the Statistical Package for the Social Sciences version 23.0.
Results
The CHA group (n = 40) demonstrated significantly lower mean intraoperative blood loss (47.8 ± 10.5 mL) compared to the control group (101.2 ± 20.3 mL; P < 0.001). Surgical field visibility was superior in the CHA group, with 72.5% of cases rated as excellent/good versus 7.5% in controls (P < 0.001). No significant difference in surgery duration or major complications was observed between the groups.
Conclusion
CHA significantly reduces blood loss and improves surgical field visibility in micro-ear surgery without increasing operative time or major complications. It is a recommended technique for optimizing surgical conditions in these delicate procedures.
Zitieren
APA
Nurullah, M., Uddin, M. J., & Abyaz, R. (2026). Effect of controlled hypotensive anesthesia on intraoperative blood loss and surgical field visibility in micro-ear surgery. Annals of International Medical and Dental Research, 12(1), 85-90. https://doi.org/10.53339/aimdr.2026.12.1.14
Vancouver
Nurullah M, Uddin MJ, Abyaz R. Effect of controlled hypotensive anesthesia on intraoperative blood loss and surgical field visibility in micro-ear surgery. Annals of International Medical and Dental Research. 2026;12(1):85-90. doi:10.53339/aimdr.2026.12.1.14
BibTeX
@article{Nurullah2026,
author = {Nurullah, Md. and Uddin, Md. Jashim and Abyaz, Rafiz},
title = {Effect of controlled hypotensive anesthesia on intraoperative blood loss and surgical field visibility in micro-ear surgery},
journal = {Annals of International Medical and Dental Research},
year = {2026},
volume = {12},
number = {1},
pages = {85--90},
doi = {10.53339/aimdr.2026.12.1.14}
}
EUVIMED