Nanoscope-assisted release of the lacertus fibrosus: A cadaveric study of feasibility, visualization, and anatomical safety
World Journal of Orthopedics · 18.08.2026 · 17 (8)
DOI: 10.5312/wjo.123794 ↗Kurz gefasst
Fachartikel in der Zeitschrift World Journal of Orthopedics, online erschienen am 18.08.2026. Verfasst von Bartosz Chlebanowski und 5 weiteren Autor:innen. Die Arbeit nennt 26 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND Compression of the proximal median nerve beneath the lacertus fibrosus is an increasingly recognized cause of activity-related forearm weakness and reduced grip endurance. Surgical decompression is typically performed using open or mini-open techniques. The anatomical feasibility and procedural safety of a minimally invasive nanoscope-assisted release have not been systematically evaluated. AIM To evaluate the anatomical feasibility, visualization quality, and procedural safety of nanoscope-assisted lacertus fibrosus release in a cadaveric model, with systematic open dissection used to confirm completeness of release and preservation of adjacent neurovascular structures. METHODS Twenty fresh-frozen cadaveric upper limbs underwent lacertus fibrosus release using a 1.9-mm 0° nanoscope system. Feasibility, operative time, and visualization quality were assessed. Visualization of the median nerve, lacertus fibrosus, and brachial artery was independently graded by two surgeons using a 5-point Likert scale. Systematic open dissection was subsequently performed to confirm completeness of release and assess for iatrogenic neurovascular injury. RESULTS Nanoscope-assisted release was successfully completed in all 20 specimens without conversion to an open procedure. Mean operative time was 6.9 ± 0.8 minutes. Mean visualization scores were 4.8 ± 0.3 for the median nerve, 4.9 ± 0.1 for the lacertus fibrosus, and 4.6 ± 0.4 for the brachial artery, with good interobserver agreement (intraclass correlation coefficient = 0.88). Open validation confirmed complete release in all specimens, with no residual constricting fibers or visible iatrogenic neurovascular injury. CONCLUSION Nanoscope-assisted lacertus fibrosus release was anatomically feasible and demonstrated a favorable procedural safety profile in this cadaveric model. Systematic open validation confirmed complete release and preservation of adjacent neurovascular structures in all specimens. These findings provide an anatomical foundation for prospective clinical evaluation.
Zitieren
APA
Chlebanowski, B., Wojtowicz, B. G., Urban, K., Kanak, M., Domzalski, M., & Lesman, J. (2026). Nanoscope-assisted release of the lacertus fibrosus: A cadaveric study of feasibility, visualization, and anatomical safety. World Journal of Orthopedics, 17(8). https://doi.org/10.5312/wjo.123794
Vancouver
Chlebanowski B, Wojtowicz BG, Urban K, Kanak M, Domzalski M, Lesman J. Nanoscope-assisted release of the lacertus fibrosus: A cadaveric study of feasibility, visualization, and anatomical safety. World Journal of Orthopedics. 2026;17(8). doi:10.5312/wjo.123794
BibTeX
@article{Chlebanowski2026,
author = {Chlebanowski, Bartosz and Wojtowicz, Blazej G and Urban, Karolina and Kanak, Michal and Domzalski, Marcin and Lesman, Jędrzej},
title = {Nanoscope-assisted release of the lacertus fibrosus: A cadaveric study of feasibility, visualization, and anatomical safety},
journal = {World Journal of Orthopedics},
year = {2026},
volume = {17},
number = {8},
doi = {10.5312/wjo.123794}
}
EUVIMED