Considerations on Switching Capability of Circuit Breakers under Earth Fault in Electrical Grid
Annals of the University of Craiova Electrical Engineering Series · 26.02.2026 · 49 · 10-15
DOI: 10.52846/aucee.2025.02 ↗Kurz gefasst
Fachartikel in der Zeitschrift Annals of the University of Craiova Electrical Engineering Series, online erschienen am 31.01.2026. Verfasst von Cristian-Eugeniu Sălceanu und 4 weiteren Autor:innen. Die Arbeit nennt 12 Literaturangaben.
Abstract (Originalsprache)
Circuit-breakers are essential for the safety and reliability of electrical power systems by interrupting fault currents un-der various conditions. Circuit-breakers must be capable of breaking single-phase short-circuit currents which can occur in two distinct scenarios. The first scenario involves effective-ly earthed neutral systems, where single-phase faults can generate high fault currents that the circuit-breaker must safely interrupt to prevent equipment damage and ensure personnel safety. The second scenario occurs in non-effectively earthed neutral systems, where double earth faults can appear on two separate phases, with one fault occurring on one side of the circuit-breaker and the other on the opposite side. Such conditions pose significant challenges for circuit-breaker design and operation, requiring careful consideration of their dynamic response and fault current interruption capacity. This paper presents the expected be-havior of the circuit breakers and the real-life situations encountered during high-power testing of this type of equipment. Real-life testing reveals critical insights into per-formance limitations, transient phenomena, and operational reliability, providing valuable information for both equip-ment manufacturers and system designers. The study high-lights the importance of accurate modeling, thorough test-ing, and adherence to standards to ensure that circuit-breakers perform reliably under all anticipated fault condi-tions. The most severe condition is identified as a double earth fault occurring under phase opposition. Although additional tests are planned to confirm this, preliminary assessment suggests that under normal operating conditions (0° φ 30°), the current at the final breaking pole should not exceed the generator’s short-circuit current.
Zitieren
APA
Sălceanu, C., Iovan, D., Ocoleanu, D., Boncea, M., & Seitan, S. (2026). Considerations on Switching Capability of Circuit Breakers under Earth Fault in Electrical Grid. Annals of the University of Craiova Electrical Engineering Series, 49, 10-15. https://doi.org/10.52846/aucee.2025.02
Vancouver
Sălceanu C, Iovan D, Ocoleanu D, Boncea M, Seitan S. Considerations on Switching Capability of Circuit Breakers under Earth Fault in Electrical Grid. Annals of the University of Craiova Electrical Engineering Series. 2026;49:10-15. doi:10.52846/aucee.2025.02
BibTeX
@article{Slceanu2026,
author = {Sălceanu, Cristian-Eugeniu and Iovan, Daniela and Ocoleanu, Daniel-Constantin and Boncea, Marius and Seitan, Stefan-Marius},
title = {Considerations on Switching Capability of Circuit Breakers under Earth Fault in Electrical Grid},
journal = {Annals of the University of Craiova Electrical Engineering Series},
year = {2026},
volume = {49},
pages = {10--15},
doi = {10.52846/aucee.2025.02}
}
EUVIMED