EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Performance Evaluation of PV-CSP Hybrid Power Plants With Power-to-Heat Integration

Zahra Mahdi, Klaus Görner, Christoph Wieland, Ulf Herrmann

SolarPACES Conference Proceedings · 17.11.2026 · 4

DOI: 10.52825/solarpaces.v4i.3016 ↗

Kurz gefasst

Fachartikel in der Zeitschrift SolarPACES Conference Proceedings, online erschienen am 17.11.2026. Verfasst von Zahra Mahdi und 3 weiteren Autor:innen. Die Arbeit nennt 12 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Hybrid photovoltaic - concentrated solar power (PV-CSP) systems combine the cost-effectiveness of PV with the dispatchability of CSP together with the thermal energy storage (TES). However, their accurate modeling requires balancing physical detail with computational efficiency. This study presents an evaluation and improvement of the Solar Plant Optimization Tool (SPOT), a quasi-dynamic simulation framework designed for fast yield estimation and optimization of hybrid PV-CSP plants. A detailed dynamic model developed in Modelica, Dymola serves as the reference for comparison and improvement. The initial analysis revealed that SPOT tends to overestimate parabolic trough collector (PTC) output due to simplified loss representations and the absence of component inertia. To address these discrepancies, three improvement steps were implemented: (i) introduction of an empirical correction factor for PTC thermal losses, (ii) representation of the heat exchanger (HX) and electric heater (EH) as control volumes with thermal inertia, and (iii) inclusion of PTC start-up delay. The combined effect of these enhancements reduced deviations in stored energy from ~2.0% to 0.34% compared to the dynamic model, with consistent accuracy across different temporal resolutions. In addition to improving accuracy, SPOT achieves exceptional computational performance of over 5000 times faster speed. These results demonstrate that the improved SPOT model offers a reliable and computationally efficient alternative to detailed simulations, making it particularly suitable for system design studies, parametric analysis, and optimization of hybrid PV-CSP plants.

Zitieren

APA

Mahdi, Z., Görner, K., Wieland, C., & Herrmann, U. (2026). Performance Evaluation of PV-CSP Hybrid Power Plants With Power-to-Heat Integration. SolarPACES Conference Proceedings, 4. https://doi.org/10.52825/solarpaces.v4i.3016

Vancouver

Mahdi Z, Görner K, Wieland C, Herrmann U. Performance Evaluation of PV-CSP Hybrid Power Plants With Power-to-Heat Integration. SolarPACES Conference Proceedings. 2026;4. doi:10.52825/solarpaces.v4i.3016

BibTeX
@article{Mahdi2026,
  author = {Mahdi, Zahra and Görner, Klaus and Wieland, Christoph and Herrmann, Ulf},
  title = {Performance Evaluation of PV-CSP Hybrid Power Plants With Power-to-Heat Integration},
  journal = {SolarPACES Conference Proceedings},
  year = {2026},
  volume = {4},
  doi = {10.52825/solarpaces.v4i.3016}
}
Kostenlos starten →