Design and Optimization of a Decentralized Hybrid Solar–Wind Microgrid with Battery Energy Storage for Enhanced Power Quality and Grid Resilience
Journal of Electrical Systems · 23.04.2026 · 20 (3) · 9806-9811
DOI: 10.52783/jes.9556 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Electrical Systems, online erschienen am 23.04.2026. Verfasst von Maheshwaram Bhanu Chandar. Der Volltext ist frei zugänglich (Open Access, CC BY-ND 4.0).
Abstract (Originalsprache)
This scientific investigation elaborates on a paradigm-shifting design and optimization methodology for a decentralized hybrid solar-wind microgrid inherently coupled with a Battery Energy Storage System (BESS). Contemporary power networks grapple with the dual predicaments of maintaining rigorous power quality and ensuring uninterrupted grid resilience amidst extreme load perturbations. This research resolves these bottlenecks through a structurally novel decentralized control architecture, fortified by a computationally efficient hybrid Particle Swarm Optimization (PSO) heuristic dispatch mechanism. Unlike orthodox centralized Energy Management Systems (EMS) that suffer from vulnerability to trans-nodal communication latency, or elementary decentralized droop strategies that fundamentally forfeit economic optimality, the proposed framework structurally integrates localized hardware-level transient suppression with globally aware cost-minimization. Within this context, the study mathematically formulates the nonlinear dynamic behaviors of a 500 kW photovoltaic matrix, a 350 kW wind turbine generation unit, and an 800 kWh capacity BESS. The multi-objective optimization algorithm strategically isolates and suppresses Total Harmonic Distortion (THD) below 2.8%, actively mitigates cyclic battery capacity degradation, and ensures levelized economic dispatch. The analytical models were exhaustively validated using MATLAB/Simulink Simscape libraries subjected to extreme transient load profiling. Results demonstrate an extraordinary voltage settling sequence within 0.15 seconds trailing severe load disturbances—vastly superior to the 0.40 seconds exhibited by standard PI-centric decentralization. Concurrently, the algorithmic dispatch reduced cumulative operational expenditures by 14.6% against benchmark rule-based predictive models, confirming the exceptional efficacy of hybridizing local physical-layer governance with heuristic global optimization in renewable-dense topologies.
Zitieren
APA
Chandar, M. B. (2026). Design and Optimization of a Decentralized Hybrid Solar–Wind Microgrid with Battery Energy Storage for Enhanced Power Quality and Grid Resilience. Journal of Electrical Systems, 20(3), 9806-9811. https://doi.org/10.52783/jes.9556
Vancouver
Chandar MB. Design and Optimization of a Decentralized Hybrid Solar–Wind Microgrid with Battery Energy Storage for Enhanced Power Quality and Grid Resilience. Journal of Electrical Systems. 2026;20(3):9806-9811. doi:10.52783/jes.9556
BibTeX
@article{Chandar2026,
author = {Chandar, Maheshwaram Bhanu},
title = {Design and Optimization of a Decentralized Hybrid Solar–Wind Microgrid with Battery Energy Storage for Enhanced Power Quality and Grid Resilience},
journal = {Journal of Electrical Systems},
year = {2026},
volume = {20},
number = {3},
pages = {9806--9811},
doi = {10.52783/jes.9556}
}