Optic Cup and Optic Disc Segmentation Based on improved TransUnet
Journal of Electrical Systems · 03.05.2024 · 20 (7s) · 586-593
DOI: 10.52783/jes.3362 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Electrical Systems, online erschienen am 03.05.2024. Verfasst von Lina Jia. Die Arbeit wurde bisher 1-mal zitiert (Crossref). Der Volltext ist frei zugänglich (Open Access, CC BY-ND 4.0).
Abstract (Originalsprache)
Glaucoma ranks as the second leading cause of blindness globally, surpassed only by cataracts. It inflicts irreversible harm to the optic nerve, and once vision is lost, restoration is unattainable for life[1]. Therefore, early detection of glaucoma is imperative.The cup-to-disc ratio serves as a primary diagnostic tool for identifying glaucoma. Generally, an excessively large cup-to-disc ratio in fundus photographs strongly suggests glaucoma. However, human error in diagnosing fundus photographs by clinicians is prevalent, leading to time-consuming, labor-intensive, expensive, and potentially inaccurate diagnoses during extensive screenings.To combat this challenge, an enhanced TransUnet-based method is proposed for optic cup and optic disc segmentation, aiding clinicians in large-scale glaucoma screenings. The model incorporates the Focus structure and CBAM structure. The Focus structure addresses information loss during single downsampling of images, preserving more data without changing image dimensions. Meanwhile, the CBAM structure integrates channel and spatial attention, enhancing the model's ability to extract features.On the ORIGA-650 dataset, this enhanced method achieved a mean Dice coefficient of 0.984 for the disc and 0.947 for the cup, along with a mean IOU value of 0.968 for the disc and 0.902 for the cup. Compared to alternative algorithms, the segmentation results exhibit superior accuracy, showcasing the efficacy of our proposed model.
Zitieren
APA
Jia, L. (2024). Optic Cup and Optic Disc Segmentation Based on improved TransUnet. Journal of Electrical Systems, 20(7s), 586-593. https://doi.org/10.52783/jes.3362
Vancouver
Jia L. Optic Cup and Optic Disc Segmentation Based on improved TransUnet. Journal of Electrical Systems. 2024;20(7s):586-593. doi:10.52783/jes.3362
BibTeX
@article{Jia2024,
author = {Jia, Lina},
title = {Optic Cup and Optic Disc Segmentation Based on improved TransUnet},
journal = {Journal of Electrical Systems},
year = {2024},
volume = {20},
number = {7s},
pages = {586--593},
doi = {10.52783/jes.3362}
}
EUVIMED