DIAGNOSTIC ACCURACY OF MAGNETIC RESONANCE IMAGING IN ANTERIOR CRUCIATE LIGAMENT TEAR TAKING ARTHROSCOPY AS GOLD STANDARD
Journal of Medical Sciences · 31.03.2026 · 34 (1) · 4-9
DOI: 10.52764/jms.26.34.1.1 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Medical Sciences, online erschienen am 31.03.2026. Verfasst von Waqar Ali und 7 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objective
To determine the diagnostic accuracy of Magnetic Resonance Imaging (MRI) in detecting anterior cruciate ligament (ACL) tears, using arthroscopy as the gold standard. Material And Methods: We conducted this cross-sectional validation study in the Orthopedics Department at Khyber Teaching Hospital, Peshawar. A total of 296 patients were enrolled. All participants underwent knee MRI and were compared with arthroscopic findings, which served as the reference standard. Diagnostic parameters and overall accuracy were calculated. Statistical analysis was performed using SPSS 25.
Results
Of the 296 patients, MRI detected ACL tears in 172 (58.1%) cases, while arthroscopy confirmed tears in 197 (66.6%) cases. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of MRI were 70.1%, 65.7%, 80.1%, and 52.4%, respectively, with an overall diagnostic accuracy of 68%. A statistically significant association was observed between MRI and arthroscopy findings (p< 0.01). The ROC curve demonstrated fair discriminative ability of MRI.
Conclusion
MRI exhibits moderate diagnostic accuracy in detecting ACL tears, with a reliable predictive value when results are positive. However, its limited sensitivity and specificity in this context highlight the need for cautious interpretation, especially in MRI-negative cases. Arthroscopy remains the definitive diagnostic tool, particularly for ambiguous or complex injuries. Keywords: Anterior Cruciate Ligament Injuries, Magnetic Resonance Imaging, Arthroscopy
Zitieren
APA
Ali, W., Shah, S. D. A., Khan, L., Ali, A., Raza, M. M., Khan, Z., Ullah, S., & Hassan, R. E. (2026). DIAGNOSTIC ACCURACY OF MAGNETIC RESONANCE IMAGING IN ANTERIOR CRUCIATE LIGAMENT TEAR TAKING ARTHROSCOPY AS GOLD STANDARD. Journal of Medical Sciences, 34(1), 4-9. https://doi.org/10.52764/jms.26.34.1.1
Vancouver
Ali W, Shah SDA, Khan L, Ali A, Raza MM, Khan Z, et al. DIAGNOSTIC ACCURACY OF MAGNETIC RESONANCE IMAGING IN ANTERIOR CRUCIATE LIGAMENT TEAR TAKING ARTHROSCOPY AS GOLD STANDARD. Journal of Medical Sciences. 2026;34(1):4-9. doi:10.52764/jms.26.34.1.1
BibTeX
@article{Ali2026,
author = {Ali, Waqar and Shah, Syed Dilbagh Ali and Khan, Luqman and Ali, Aftab and Raza, Muhammad Maaz and Khan, Zeeshan and Ullah, Safeer and Hassan, Rao Erbaz},
title = {DIAGNOSTIC ACCURACY OF MAGNETIC RESONANCE IMAGING IN ANTERIOR CRUCIATE LIGAMENT TEAR TAKING ARTHROSCOPY AS GOLD STANDARD},
journal = {Journal of Medical Sciences},
year = {2026},
volume = {34},
number = {1},
pages = {4--9},
doi = {10.52764/jms.26.34.1.1}
}
EUVIMED