Statistical Modelling and Optimization of Boiler Economiser Thermal Performance
International Journal of Experimental Research and Review · 30.08.2026 · 51 · 151-159
DOI: 10.52756/ijerr.2026.v51.010 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Experimental Research and Review, online erschienen am 30.08.2026. Verfasst von Seema Borde und 1 weiteren Autor:innen. Die Arbeit nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
A computational and statistical approach is presented for improving heat recovery in a representative staggered tube economiser associated with a Combloc UFS 15 boiler. The Box-Behnken design was used to arrange a 3 factor, 13 run computational fluid dynamics (CFD) case. Tube outside diameter, transverse pitch and flue gas inlet velocity were varied over 38-50 mm, 65-85 mm and 4-6 m/s, respectively. A reduced quadratic response surface (intercept, linear and squared terms) was fitted to the tabulated heat transfer rates which ranged from 60.5 to 91.8 kW. The reduced model explained 98.78% of the response variation, with an adjusted coefficient of determination of 97.55% and a residual standard deviation of 1.569 kW. Gas velocity produced the largest fitted response change, followed by tube diameter and transverse pitch. The best tested design delivered 91.8 kW at 50 mm diameter, 75 mm pitch and 6 m/s. Constrained model optimization selected 50 mm diameter, 65 mm pitch and 6 m/s, predicting 95.59 kW. The confirmation CFD simulation yielded a heat transfer rate of 92.90 kW, a relative deviation from the model-predicted value of 95.59 kW, based on CFD result. Compared with the baseline heat transfer rate of 76.20 kW at the centre condition, the confirmed configuration achieved a 21.92% enhancement in heat transfer performance, partly due to the increased gas flow velocity of 6m/s. The optimum is model dependent and a sensitivity check performed on the full quadratic model (including interaction terms) predicted 97.41 kW at the same point. These findings demonstrate the effectiveness of Response Surface Methodology (RSM) in identifying a promising economiser configuration for improved thermal energy recovery. However, further investigation of pressure drop characteristics, hydraulic performance, numerical convergence and experimental validation is necessary to establish the practical feasibility and operational reliability of the proposed design. on of 2.89% from the model-predicted value of 95.59 kW, calculated with reference to the CFD result. Compared with the baseline heat transfer rate of 76.20 kW at the centre condition, the optimized configuration achieved a 21.92% enhancement in heat transfer performance. These findings demonstrate the effectiveness of Response Surface Methodology (RSM) in identifying a promising economiser configuration for improved thermal energy recovery. However, further investigation of pressure drop characteristics, hydraulic performance, numerical convergence and experimental validation is necessary to establish the practical feasibility and operational reliability of the proposed design.
Zitieren
APA
Borde, S., & Nikalje, A. (2026). Statistical Modelling and Optimization of Boiler Economiser Thermal Performance. International Journal of Experimental Research and Review, 51, 151-159. https://doi.org/10.52756/ijerr.2026.v51.010
Vancouver
Borde S, Nikalje A. Statistical Modelling and Optimization of Boiler Economiser Thermal Performance. International Journal of Experimental Research and Review. 2026;51:151-159. doi:10.52756/ijerr.2026.v51.010
BibTeX
@article{Borde2026,
author = {Borde, Seema and Nikalje, Aniruddha},
title = {Statistical Modelling and Optimization of Boiler Economiser Thermal Performance},
journal = {International Journal of Experimental Research and Review},
year = {2026},
volume = {51},
pages = {151--159},
doi = {10.52756/ijerr.2026.v51.010}
}