Abstract (Originalsprache)

Our study aims to develop and validate a newly precise analysis method for simultaneous determination of metalaxyl-M and azoxystrobin residues in wastewater samples. The analysis was done by a series-200 HPLC equipped with a UV detector and C18 column used for separation. Chromatographic separation utilized a mobile phase of 60% acetonitrile and 40% water by volume flowing at a constant rate of 1.2 mL/min and the quantification was performed by measuring absorbance at 275 nm. The proposed method was systematically validated in terms of linearity, accuracy, precision, recovery, limit of detection (LOD), and limit of quantification (LOQ) in compliance with SANCO/3030/99 rev.5 requirements. Calibration curves exhibited excellent linearity (R² > 0.990) across the tested concentration ranges. The obtained LOD and LOQ values indicated high method sensitivity, enabling the reliable quantification of trace levels in complex wastewater matrices. Recovery tests performed at three spiking levels demonstrated satisfactory recoveries ranging from 100.2% to 101.3% for metalaxyl-M and from 99.7% to 101.2% for azoxystrobin, confirming the robustness and reliability of the developed procedure. Overall, the validated HPLC method serves as a versatile, rapid, and economical analytical tool applicable to different environmental and agricultural samples for the monitoring of fungicide residues.

Zitieren

APA

Elkamhawy, I. M., Eladaoy, M. A., & Emara, M. G. (2026). A reliable, fast, and cost-effective chromatographic method for concurrent detection of Metalaxyl-m and azoxystrobin in wastewater: A tool for environmental pollution monitoring. Current Chemistry Letters, 15(2), 295-304. https://doi.org/10.5267/j.ccl.2026.1.007

Vancouver

Elkamhawy IM, Eladaoy MA, Emara MG. A reliable, fast, and cost-effective chromatographic method for concurrent detection of Metalaxyl-m and azoxystrobin in wastewater: A tool for environmental pollution monitoring. Current Chemistry Letters. 2026;15(2):295-304. doi:10.5267/j.ccl.2026.1.007

BibTeX
@article{Elkamhawy2026,
  author = {Elkamhawy, Ismael M. and Eladaoy, Mahmoud A. and Emara, Mostafa G.},
  title = {A reliable, fast, and cost-effective chromatographic method for concurrent detection of Metalaxyl-m and azoxystrobin in wastewater: A tool for environmental pollution monitoring},
  journal = {Current Chemistry Letters},
  year = {2026},
  volume = {15},
  number = {2},
  pages = {295--304},
  doi = {10.5267/j.ccl.2026.1.007}
}
Kostenlos starten →