Determination of Gallstone Composition using Dual-Energy Computed Tomography: An Ex-vivo Study

Seonghyun Wee, Young Hwan Lee, Youe Ree Kim, Kwon Ha Yoon, Dong-Eun Park

Korean Journal of Abdominal Radiology · 15.07.2021 · 5 (1) · 42-52

DOI: 10.52668/kjar.2021.00080 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Korean Journal of Abdominal Radiology, erschienen am 15.07.2021. Verfasst von Seonghyun Wee und 4 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This study aimed to investigate whether ex-vivo gallstones are distinguishable by type using dualenergy computed tomography (DECT).Materials and Methods: A total of 124 gallstones from 65 patients with acute or chronic calculous cholecystitis were evaluated using DECT. The extracted gallstones were submerged in distilled water in an acrylic container and scanned at tube voltages of 80/140 kVp and 100/140 kVp. The images were grouped into three sets: 80, 100, and 140 kVp. Qualitative analyses of DECT sensitivity and attenuation patterns in each image set were performed, and quantitative analyses included calculation of mean attenuation values and measurement of the gallstone size. Semi-quantitative Fourier transform infrared (FTIR) spectroscopy was used as the reference standard to confirm the chemical composition of the gallstones.

Results

FTIR spectroscopy identified 66 gallstones from 33 patients as cholesterol gallstones and 58 gallstones from 32 patients as pigment gallstones. Qualitative analysis indicated that DECT sensitivity for cholesterol gallstones was greatest at 80 kVp. Most cholesterol gallstones (79%) showed low attenuation at 80 kVp and high attenuation (65%) at 140 kVp. Pigment gallstones demonstrated high attenuation at all image sets. On quantitative analysis, the mean calculated attenuation values of cholesterol gallstones were -17 ± 50 Hounsfield Units (HU), -5.1 ± 43 HU, and 19.2 ± 39 HU at 80, 100, and 140 kVp, respectively, and 342 ± 173 HU, 286 ± 116 HU, and 195 ± 91 HU, respectively, for pigment stones.

Conclusions

Ex-vivo gallstones were distinguishable as cholesterol or pigment gallstones by using DECT.

Zitieren

APA

Wee, S., Lee, Y. H., Kim, Y. R., Yoon, K. H., & Park, D. (2021). Determination of Gallstone Composition using Dual-Energy Computed Tomography: An Ex-vivo Study. Korean Journal of Abdominal Radiology, 5(1), 42-52. https://doi.org/10.52668/kjar.2021.00080

Vancouver

Wee S, Lee YH, Kim YR, Yoon KH, Park D. Determination of Gallstone Composition using Dual-Energy Computed Tomography: An Ex-vivo Study. Korean Journal of Abdominal Radiology. 2021;5(1):42-52. doi:10.52668/kjar.2021.00080

BibTeX
@article{Wee2021,
  author = {Wee, Seonghyun and Lee, Young Hwan and Kim, Youe Ree and Yoon, Kwon Ha and Park, Dong-Eun},
  title = {Determination of Gallstone Composition using Dual-Energy Computed Tomography: An Ex-vivo Study},
  journal = {Korean Journal of Abdominal Radiology},
  year = {2021},
  volume = {5},
  number = {1},
  pages = {42--52},
  doi = {10.52668/kjar.2021.00080}
}
Kostenlos starten →