Fachartikel in der Zeitschrift Korean Journal of Abdominal Radiology, 2021. Verfasst von Cheong-Il Shin und 4 weiteren Autor:innen. Die Arbeit nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: National Research Foundation of Korea, Ministry of Science, ICT and Future Planning.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To evaluate the feasibility of ultra-low dose 80 kVp CT for the evaluation of inflammatory bowel disease (IBD) in a rabbit model and to investigate the effect of two different iterative reconstruction (IR) algorithms on 80 kVp CT in terms of image quality and diagnostic performance in comparison with same session conventional 120 kVp images.Materials and Methods: This study was approved by the Animal Care and Use Committee of our hospital. Twenty-eight New Zealand white rabbits were randomly divided into two groups: IBD group (n=18) and a control group (n=10). To create an acute IBD model, 3mL of a 5% w/v tri-nitrobenzene sulfonic acid solution was administered to the sigmoid colon of the rabbits. CT was performed at 80 kVp and 120 kVp and was reconstructed using filtered back projection (FBP), hybrid statistic-based IR, and full IR algorithms for 80 kVp and using FBP only for 120 kVp. Effective radiation dose, image noise, image quality, and diagnostic performance by two reviewers were recorded and compared using repeated measure analysis of variance, McNemar test, and receiver operating curve (ROC) analysis.

Results

Mean effective radiation dose of 80 kVp CT (0.05 mSv) was significantly lower than that (0.285 mSv) of 120 kVp CT. Mean image noise was highest in the 80 kVp FBP setting (60.36) but significantly decreased with IR algorithms (47.02 with hybrid IR and 12.92 with full IR) (P

Förderung

  • National Research Foundation of Korea
  • Ministry of Science, ICT and Future Planning

Zitieren

APA

Shin, C., Kim, S. H., Yu, M. H., Joo, I., & Han, J. K. (2021). Effect of Different Iterative Reconstruction Algorithms on Ultra-Low Dose CT of Inflammatory Bowel Disease in a Rabbit Model. Korean Journal of Abdominal Radiology. https://doi.org/10.52668/kjar.2021.00059

Vancouver

Shin C, Kim SH, Yu MH, Joo I, Han JK. Effect of Different Iterative Reconstruction Algorithms on Ultra-Low Dose CT of Inflammatory Bowel Disease in a Rabbit Model. Korean Journal of Abdominal Radiology. 2021. doi:10.52668/kjar.2021.00059

BibTeX
@article{Shin2021,
  author = {Shin, Cheong-Il and Kim, Se Hyung and Yu, Mi Hye and Joo, Ijin and Han, Joon Koo},
  title = {Effect of Different Iterative Reconstruction Algorithms on Ultra-Low Dose CT of Inflammatory Bowel Disease in a Rabbit Model},
  journal = {Korean Journal of Abdominal Radiology},
  year = {2021},
  doi = {10.52668/kjar.2021.00059}
}
Kostenlos starten →