EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Electrophysical Conditions for Leader Formation During Electrical Breakdown by High-Voltage Pulses of Long Air Gap in a Two-Electrode “Point-Plane” Discharge System

M. Baranov

Elektronnaya Obrabotka Materialov · 2026-03 · 62 (1) · 27-42

DOI: 10.52577/eom.2026.62.1.27 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Elektronnaya Obrabotka Materialov, 2026-03. Verfasst von M. Baranov. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The article presents the results of a computational and experimental determinationы of the electrophysical conditions for the emergence of a leader channel during an electrical breakdown of a long air gap in a point-to-plane two-electrode discharge system (TEDS) using a standard high-voltage aperiodic switching pulse with a time shape of Tm/Тp ≈ 200 μs /1990 μs and a positive polarity. A novel engineering approach to the substantiated selection of the key indicator of the streamer-leader transition in a long air gap in the TEDS is proposed, allowing to formulate the fundamental conditions for its onset and the emergence of a positive leader in the TEDS. Calculation relationships have been obtained for determining: the radius ri of the zone of an active impact ionization by air electrons near the potential electrode of the TEDS; the electron density nes in the channel of the developed streamer in the specified air ionization zone; the maximum electron temperature Tms in the channel of this streamer, transformed into a positive leader. The high-voltage experiments carried out confirmed the emergence in a long air gap of the TEDS (lmin = 1.5 m; Ud ≈ 611.6 kV) near its potential steel point electrode (r0 ≈ 15 mm; rc ≈ 3 mm) of a bright spherical zone with a radius of ri ≈ 30 mm of an intense ionization by electron impacts on the air, from which a plasma channel of a positive leader continuously develops towards the grounded steel plane of the TEDS at a speed of vL ≈ 105 m/s.

Zitieren

APA

Baranov, M. (2026). Electrophysical Conditions for Leader Formation During Electrical Breakdown by High-Voltage Pulses of Long Air Gap in a Two-Electrode “Point-Plane” Discharge System. Elektronnaya Obrabotka Materialov, 62(1), 27-42. https://doi.org/10.52577/eom.2026.62.1.27

Vancouver

Baranov M. Electrophysical Conditions for Leader Formation During Electrical Breakdown by High-Voltage Pulses of Long Air Gap in a Two-Electrode “Point-Plane” Discharge System. Elektronnaya Obrabotka Materialov. 2026;62(1):27-42. doi:10.52577/eom.2026.62.1.27

BibTeX
@article{Baranov2026,
  author = {Baranov, M.},
  title = {Electrophysical Conditions for Leader Formation During Electrical Breakdown by High-Voltage Pulses of Long Air Gap in a Two-Electrode “Point-Plane” Discharge System},
  journal = {Elektronnaya Obrabotka Materialov},
  year = {2026},
  volume = {62},
  number = {1},
  pages = {27--42},
  doi = {10.52577/eom.2026.62.1.27}
}
Kostenlos starten →