EUVIMEDEUVIMED entdecken
Crossref

Spatial Computing With the Apple Vision Pro in Minimally Invasive Procedure Simulation: a randomized crossover feasibility study

Sydney Cooper, Aaron Kyle Jones, Rahul Anil Sheth, Koustav Pal, Bruno Odisio, Mark Blaylock, Shelita Kimble, Justin Bird, David Rice, Daniel Shoenthal, Emil Patel, Vipin Kamath und 3 weitere

Advances in Cancer Education and Quality Improvement · 2026-04 · 2 (1)

DOI: 10.52519/aceqi.26.2.1.a4 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advances in Cancer Education and Quality Improvement, 2026-04. Verfasst von Sydney Cooper und 14 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This study aimed to evaluate the feasibility of wearing the Apple Vision Pro (AVP), a mixed-reality headset that integrates augmented and virtual reality, while performing minimally invasive procedures. While studies have demonstrated that spatial computing technology can improve surgical precision and reduce the risks of surgical complications, to our knowledge, no studies have specifically addressed the impact of the AVP on task performance during simulated image-guided procedures. Materials and Methods: Thirteen diagnostic and interventional radiology residents performed image-guided central venous catheter placement, thoracentesis, and paracentesis on simulation models. Each participant completed a non-timed practice followed by the procedures once with and once without the AVP, in a randomized order. The total procedure completion times were compared using a paired t test. Subsequently, we administered a questionnaire, using a Likert scale (1-10), to obtain quantitative data on the operators’ perception of the headset.

Results

For paracentesis, the mean completion time was 47 seconds with the AVP headset compared to 57 seconds without (P = .129). For thoracentesis, the mean completion time was 58 seconds with the AVP, compared to 63 seconds without (P = .563). For central venous catheter insertion, the mean completion time was 168 seconds with the AVP, compared to 132 seconds without (P = .059). Across all tasks, there was no statistically significant difference in mean procedure times, indicating the AVP headset does not affect procedural efficiency. Quantitative feedback demonstrated a mean Likert score of 7.9 for positive overall experience and 7.8 for safety while performing procedures, where higher scores reflect a more favorable perception. Conversely, scores of 6.1 for device heaviness, 3.5 for hand-eye coordination, and 3.7 for perceived negative impact on procedure performance suggest a poorer experience for these aspects.

Conclusion

The AVP headset demonstrated comparable procedure completion times in minimally invasive procedure simulations. While participants noted the heaviness of the headset and that hand-eye coordination was somewhat impaired, they reported a generally favorable experience using the headset and most felt confident performing minor procedures while wearing the device. These results suggest that spatial computing headsets have potential applications in image-guided procedures and provide the basis for further evaluation in real-world operative settings.

Zitieren

APA

Cooper, S., Jones, A. K., Sheth, R. A., Pal, K., Odisio, B., Blaylock, M., Kimble, S., Bird, J., Rice, D., Shoenthal, D., Patel, E., Kamath, V., Gupta, S., Siewerdsen, J., & Kuban, J. (2026). Spatial Computing With the Apple Vision Pro in Minimally Invasive Procedure Simulation: a randomized crossover feasibility study. Advances in Cancer Education and Quality Improvement, 2(1). https://doi.org/10.52519/aceqi.26.2.1.a4

Vancouver

Cooper S, Jones AK, Sheth RA, Pal K, Odisio B, Blaylock M, et al. Spatial Computing With the Apple Vision Pro in Minimally Invasive Procedure Simulation: a randomized crossover feasibility study. Advances in Cancer Education and Quality Improvement. 2026;2(1). doi:10.52519/aceqi.26.2.1.a4

BibTeX
@article{Cooper2026,
  author = {Cooper, Sydney and Jones, Aaron Kyle and Sheth, Rahul Anil and Pal, Koustav and Odisio, Bruno and Blaylock, Mark and Kimble, Shelita and Bird, Justin and Rice, David and Shoenthal, Daniel and Patel, Emil and Kamath, Vipin and Gupta, Sanjay and Siewerdsen, Jeffrey and Kuban, Joshua},
  title = {Spatial Computing With the Apple Vision Pro in Minimally Invasive Procedure Simulation: a randomized crossover feasibility study},
  journal = {Advances in Cancer Education and Quality Improvement},
  year = {2026},
  volume = {2},
  number = {1},
  doi = {10.52519/aceqi.26.2.1.a4}
}
Kostenlos starten →