Effect of posterior-stabilized and cruciate-retaining implants on three-dimensional kinematic characteristics after total knee arthroplasty
Joint Diseases and Related Surgery · 2025
DOI: 10.52312/jdrs.2024.1836 ↗Kurz gefasst
Fachartikel in der Zeitschrift Joint Diseases and Related Surgery, 2025. Verfasst von Cheng Gu und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Joint Surgery, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou 510080, China. fuming@mail.sysu.edu.cn. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Range of Motion, Articular, Osteoarthritis, Knee, Knee Prosthesis. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
OBJECTIVES: This study aimed to analyze the effects of posteriorstabilized (PS) and cruciate-retaining (CR) total knee arthroplasty (TKA) on early postoperative three-dimensional (3D) dynamic and kinematic characteristics in patients with unilateral knee osteoarthritis (OA). PATIENTS AND METHODS: A retrospective analysis of prospectively collected data from 90 patients with unilateral TKA between February 2021 and September 2021 was conducted using a 3D kinematic analysis system before and six months after TKA. This patient group included 57 patients (10 males, 47 females; mean age: 69.5±7.5 years; range, 53 to 85 years) who underwent PS TKA and 33 patients (11 males, 22 females; mean age: 67.9±8.8 years; range, 45 to 86 years) who underwent CR TKA. The kinematic characteristics and clinical results of the two groups were compared. Clinical evaluation included the Hospital for Special Surgery knee score and range of motion (ROM). Twenty-eight healthy controls (9 males, 19 females; mean age: 64.5±2.9 years; range, 61 to 75 years) without knee OA matched for age, weight, height, and body mass index were recruited. The kinematic characteristics of the healthy control group were also evaluated. RESULTS: The PS group exhibited significant changes in basic gait parameters after TKA, including cadence (p=0.046), stride time (p=0.011), opposite foot off (p
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Joint Surgery, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou 510080, China. fuming@mail.sysu.edu.cn.
Zitieren
APA
Gu, C., Luo, X., Liu, H., Yu, B., Fu, M., & Luo, W. (2025). Effect of posterior-stabilized and cruciate-retaining implants on three-dimensional kinematic characteristics after total knee arthroplasty. Joint Diseases and Related Surgery. https://doi.org/10.52312/jdrs.2024.1836
Vancouver
Gu C, Luo X, Liu H, Yu B, Fu M, Luo W. Effect of posterior-stabilized and cruciate-retaining implants on three-dimensional kinematic characteristics after total knee arthroplasty. Joint Diseases and Related Surgery. 2025. doi:10.52312/jdrs.2024.1836
BibTeX
@article{Gu2025,
author = {Gu, Cheng and Luo, Xuming and Liu, Hailong and Yu, Baoxi and Fu, Ming and Luo, Weiliang},
title = {Effect of posterior-stabilized and cruciate-retaining implants on three-dimensional kinematic characteristics after total knee arthroplasty},
journal = {Joint Diseases and Related Surgery},
year = {2025},
doi = {10.52312/jdrs.2024.1836}
}
EUVIMED