Comparison of different internal fixation implants in the treatment of talar neck fractures: A finite element analysis
Joint Diseases and Related Surgery · 2024
DOI: 10.52312/jdrs.2023.1280 ↗Kurz gefasst
Fachartikel in der Zeitschrift Joint Diseases and Related Surgery, 2024. Verfasst von Xin Fu und 4 weiteren Autor:innen. Beteiligte Einrichtung: The First Department of Foot and Ankle Surgery, Tianjin Hospital, No. 406 Jiefangnan Road, Tianjin, 300211 People's Republic of China. hejinquan2020@…. Hauptthemen laut MEDLINE: Talus, Fractures, Bone, Fractures, Comminuted. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
OBJECTIVES: This study aimed to analyze the biomechanics of cannulated screws (CS) with or without a lateral locking plate (LLP) in talar neck fractures through a finite element analysis. PATIENTS AND METHODS: The computed tomography image of the talus from a healthy volunteer (adult male) was used to reconstruct a three-dimensional talar model. The method for fixing talar neck fractures with CS and an LLP was planned using computer-aided design software. Afterward, the three-dimensional models of comminuted talar neck fractures were used to simulate fixation with anteroposterior parallel dual CS, single CS+LLP, and dual CS+LLP. Finally, finite element analysis was carried out to compare the outcomes of dual CS+LLP to those of single CS+LLP and to those of using dual CS alone. The displacement and von Mises stress values of the three groups with different internal fixation were analyzed. RESULTS: For a simple talar neck fracture, the lowest amount of displacement was obtained with CS+LLP (0.407 mm), while dual CS (0.459 mm) showed the highest amount of total displacement; the lowest amount of peak stresses was obtained with CS+LLP (5.38 MPa), while dual CS (8.749 MPa) showed the highest amount of total peak stresses. For a comminuted talar neck fracture, the lowest amount of displacement was obtained with CS+LLP (0.398 mm), while dual CS (0.408 mm) showed the highest amount of total displacement; the lowest amount of peak stresses was obtained with CS+LLP (129.9 MPa), while dual CS (205.9 MPa) showed the highest amount of peak stresses. CONCLUSION: Compared to the other two groups, the dual CS+LLP group had better biomechanics properties in the displacement and stress peak of the talus and implant. Thus, the use of dual CS+LLP fixation is recommended for the surgical treatment of comminuted talar neck fractures.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- The First Department of Foot and Ankle Surgery, Tianjin Hospital, No. 406 Jiefangnan Road, Tianjin, 300211 People's Republic of China. hejinquan2020@126.com.
Zitieren
APA
Fu, X., Cao, H. B., Li, N., Wang, G. X., & He, J. Q. (2024). Comparison of different internal fixation implants in the treatment of talar neck fractures: A finite element analysis. Joint Diseases and Related Surgery. https://doi.org/10.52312/jdrs.2023.1280
Vancouver
Fu X, Cao HB, Li N, Wang GX, He JQ. Comparison of different internal fixation implants in the treatment of talar neck fractures: A finite element analysis. Joint Diseases and Related Surgery. 2024. doi:10.52312/jdrs.2023.1280
BibTeX
@article{Fu2024,
author = {Fu, Xin and Cao, Hong-Bin and Li, Nan and Wang, Gui-Xin and He, Jin-Quan},
title = {Comparison of different internal fixation implants in the treatment of talar neck fractures: A finite element analysis},
journal = {Joint Diseases and Related Surgery},
year = {2024},
doi = {10.52312/jdrs.2023.1280}
}
EUVIMED