Parametric fluid mechanics study of vessel geometry and blood rheology: Structural absence of a Pareto trade-off
Narra X · 18.11.2026 · 4 (3) · e353
DOI: 10.52225/narrax.v4i3.353 ↗Kurz gefasst
Fachartikel in der Zeitschrift Narra X, online erschienen am 18.11.2026. Verfasst von Tulus Tulus und 6 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Cardiovascular hemodynamics in narrowed arteries are heavily dictated by local geometry and complex fluid properties, but multi-objective optimization loops using full Navier–Stokes solves remain computationally prohibitive. The aim of this study was to evaluate a multi-objective parametric framework for non-Newtonian blood flow through stenosed arteries and determine whether competing trade-offs exist between geometric narrowing and fluid rheology. The framework combines a Gaussian-parametrized stenosis model with the Carreau–Yasuda rheological law under a reduced-order, lubrication-theory formulation. At each axial position, the model prescribes a parabolic velocity profile scaled by mass conservation, a kinematic approximation that replaces a coupled Navier–Stokes solve. Two separate parametric optimization analyses were conducted with an NSGA-II scheme over three engineering metrics (peak wall shear stress, pressure drop, and viscous energy loss). The first analysis varied stenosis severity and width with rheology fixed, whereas the second varied rheological parameter (μ₀, , ) with a severe stenosis fixed. Across four representative configurations, peak velocity and maximum wall shear stress depended on severity alone (0.57 m/s and 1.26 Pa at δ=0.3; 1.00 m/s and 3.80 Pa at δ=0.6), whereas pressure drop and energy loss also rose with stenosis width. Both algorithmic runs converged to a single corner of their mathematical domains rather than a spread Pareto front. Analytical arguments and uniform sampling grids confirmed that each objective changes monotonically with each isolated parameter, causing a single corner solution to dominate each domain. The framework demonstrates the structural behavior of the simplified fluid formulation rather than competing physical optima. An independent, transient 3D COMSOL simulation illustrated a proximal–distal pressure difference varying over the cardiac cycle (peak 3.5 mmHg) to highlight transient physical behaviors omitted by steady-state models. These findings suggest that reduced-order computational formulations structurally govern local fluid indices, demonstrating that geometry and rheology do not present a Pareto trade-off within this kinematic framework.
Zitieren
APA
Tulus, T., Marpaung, J. L., Aziz, N. A., Marpaung, T. J., Suriati, S., Syahputra, M. R., & Nasution, P. K. (2026). Parametric fluid mechanics study of vessel geometry and blood rheology: Structural absence of a Pareto trade-off. Narra X, 4(3), e353. https://doi.org/10.52225/narrax.v4i3.353
Vancouver
Tulus T, Marpaung JL, Aziz NA, Marpaung TJ, Suriati S, Syahputra MR, et al. Parametric fluid mechanics study of vessel geometry and blood rheology: Structural absence of a Pareto trade-off. Narra X. 2026;4(3):e353. doi:10.52225/narrax.v4i3.353
BibTeX
@article{Tulus2026,
author = {Tulus, Tulus and Marpaung, Jonathan L. and Aziz, Nuraini A. and Marpaung, Tulus J. and Suriati, Suriati and Syahputra, Muhammad R. and Nasution, Putri K.},
title = {Parametric fluid mechanics study of vessel geometry and blood rheology: Structural absence of a Pareto trade-off},
journal = {Narra X},
year = {2026},
volume = {4},
number = {3},
pages = {e353},
doi = {10.52225/narrax.v4i3.353}
}
EUVIMED