EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

The Efficacy of Minimally Invasive Implantable Wireless Electrical Stimulation for the Treatment of Stress Urinary Incontinence in a Rat Model

Miho Song, Jong Hyun Yun, Hyun Young Lee, Kyung Su Kim, Jahyun Koo, In Ho Choi, Franklin Don Bien, Jae Heon Kim, Seung Whan Doo

International Neurourology Journal · 31.05.2026 · 30 (Suppl 1) · S36-47

DOI: 10.5213/inj.2652012.006 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Neurourology Journal, erschienen am 31.05.2026. Verfasst von Miho Song und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Urology, Soonchunhyang University College of Medicine, Seoul, Korea. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Korea Health Industry Development Institute, Ministry of Health and Welfare.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Current therapies using midurethral sling mesh to treat stress urinary incontinence (SUI) are often considered insufficient. This study aims to evaluate the therapeutic efficacies of a minimally invasive implantable wireless electrical stimulator as an alternative treatment of SUI.

Methods

SUI was induced in 12 female, 12-week-old Sprague-Dawley rats with a deteriorated urethral sphincter complex by mechanical dilatation of the vagina. Six rats underwent sham operations. Four weeks after inducing SUI, 12 rats with SUI were divided into 2 groups. One group received a transplantation of an implantable wireless electrical stimulator, and the other midline incision and suturing. A total of 4 electrical stimulations were applied for 30 minutes twice weekly for 4 weeks in implantation model. Cystometric parameters including leak point pressure, urethral pressure and electromyography, histological examinations, immunostaining for Masson trichrome stain were measured at 4 weeks after intervention.

Results

After SUI induction, mean leak point pressure (LPP) was significantly lower in SUI groups than in controls (25.0±6.9 cm H2O vs. 62.6±4.1 cm H2O, P=0.012). At 4-week postintervention, the +ES group (SUI rat model with stimulation) demonstrated significantly higher LPP than the −ES group (48.8±8.4 cm H2O vs. 26.0±6.6 cm H2O, P=0.002). Urethral pressure showed a nonsignificant upward trend in the +ES group (SUI rat model without stimulation) compared with −ES (20.5±1.4 cm H2O vs. 18.1±1.1 cm H2O, P=0.070). Histology showed improved tissue organization with reduced inflammatory infiltration, and Masson staining demonstrated a trend toward higher collagen density in +ES (bladder: 28.3%±5.2% vs. 32.5%±7.6%, P=0.292; urethra: 44.2%±8.6% vs. 51.7%±8.2%, P=0.153).

Conclusions

These results indicate that an implantation of a wireless electrical stimulator can help to improve urethral sphincter function in SUI rat model. Moreover, the minimally invasive wireless electrical strategy may represent a promising therapeutic modality for pelvic floor muscle rehabilitation in the treatment of SUI with potential for clinical translation.

Schlagwörter

Stichwörter der Autor:innen

Electrical stimulationImplantable devicePelvic floor muscle rehabilitationStress urinary incontinenceWireless device

Autor:innen und Institutionen

  • Department of Urology, Soonchunhyang University College of Medicine, Seoul, Korea.
  • School of Biomedical Engineering, Korea University, Seoul, Korea.
  • Interdisciplinary Program in Precision Public Health, Korea University, Seoul, Korea.
  • Department of Pathology, Soonchunhyang University Seoul Hospital, Seoul, Korea.
  • Department of Electrical Engineering, Ulsan National Institute of Science and Technology, Ulsan, Korea.
  • SB Solutions Inc., Ulsan National Institute of Science and Technology, Ulsan, Korea.

Förderung

  • Korea Health Industry Development Institute
  • Ministry of Health and Welfare

Zitieren

APA

Song, M., Yun, J. H., Lee, H. Y., Kim, K. S., Koo, J., Choi, I. H., Bien, F. D., Kim, J. H., & Doo, S. W. (2026). The Efficacy of Minimally Invasive Implantable Wireless Electrical Stimulation for the Treatment of Stress Urinary Incontinence in a Rat Model. International Neurourology Journal, 30(Suppl 1), S36-47. https://doi.org/10.5213/inj.2652012.006

Vancouver

Song M, Yun JH, Lee HY, Kim KS, Koo J, Choi IH, et al. The Efficacy of Minimally Invasive Implantable Wireless Electrical Stimulation for the Treatment of Stress Urinary Incontinence in a Rat Model. International Neurourology Journal. 2026;30(Suppl 1):S36-47. doi:10.5213/inj.2652012.006

BibTeX
@article{Song2026,
  author = {Song, Miho and Yun, Jong Hyun and Lee, Hyun Young and Kim, Kyung Su and Koo, Jahyun and Choi, In Ho and Bien, Franklin Don and Kim, Jae Heon and Doo, Seung Whan},
  title = {The Efficacy of Minimally Invasive Implantable Wireless Electrical Stimulation for the Treatment of Stress Urinary Incontinence in a Rat Model},
  journal = {International Neurourology Journal},
  year = {2026},
  volume = {30},
  number = {Suppl 1},
  pages = {S36--47},
  doi = {10.5213/inj.2652012.006}
}
Kostenlos starten →