EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Deep Learning-Based Uroflowmetry Curve Analysis Improves the Noninvasive Diagnosis of Lower Urinary Tract Symptoms

Jong Hoon Lee, Yungon Lee, Kwang Jin Ko, Myung Jin Chung, Chung Un Lee, Jung Hyun Kim, Deok-Hyun Han

International Neurourology Journal · 30.11.2025 · 29 (Suppl 2) · S73-S82

DOI: 10.5213/inj.2550266.133 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Neurourology Journal, erschienen am 30.11.2025. Verfasst von Jong Hoon Lee und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Urology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: National Research Foundation of Korea, Ministry of Education, National IT Industry Promotion Agency.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This study aimed to evaluate the performance of an artificial intelligence (AI)-based analysis of uroflowmetry (UFM) curve images, enhanced with customized preprocessing techniques, to improve diagnostic accuracy for bladder outlet obstruction (BOO) and detrusor underactivity (DUA).

Methods

We retrospectively analyzed 2,579 UFM curve images from patients who underwent urodynamic study (UDS), including 725 normal and 1,854 abnormal cases (736 BOO and 1,387 DUA). A VGG16 convolutional neural network model was developed to perform 3 binary classification tasks: normal versus abnormal, BOO versus non-BOO, and DUA versus non-DUA. To improve model performance, we implemented a preprocessing pipeline consisting of denoising, cropping, axis scaling, and color-coding of clinical parameters such as voided volume and postvoid residual volume (PVR). Model performance was evaluated using 5-fold stratified cross-validation and the area under the receiver operating characteristic curve (AUROC).

Results

Abnormal cases demonstrated a lower median maximum flow rate (8.9 mL/sec vs. 14.8 mL/sec), higher PVR (60.0 mL vs. 20.0 mL), and lower voiding efficiency (78.5% vs. 92.5%) than normal cases. Within the abnormal group, the BOO subgroup showed a higher PVR (80.0 mL) than the non-BOO subgroup (30.0 mL). After applying the preprocessing pipeline, model performance improved, with AUROC increasing from 0.807±0.024 to 0.827±0.016 for normal vs. abnormal classification, from 0.749±0.019 to 0.773±0.034 for BOO classification, and from 0.693±0.016 to 0.709±0.031 for DUA classification.

Conclusions

AI-based analysis of UFM curve images, enhanced through customized preprocessing, improved diagnostic accuracy in patients with lower urinary tract symptoms, effectively identifying BOO and DUA. This noninvasive method may serve as an adjunct or screening tool to reduce reliance on invasive UDS.

Schlagwörter

Stichwörter der Autor:innen

Artificial intelligenceLower urinary tract symptomsUrinary bladder neck obstructionUroflowmetry

Autor:innen und Institutionen

  • Department of Urology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.
  • Department of Digital Health, SAIHST, Sungkyunkwan University, Seoul, Korea.
  • Medical AI Research Center, Research Institute for Future Medicine, Samsung Medical Center, Seoul, Korea.
  • Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.
  • Department of Urology, Chung-Ang University Gwangmyeong Hospital, Chung-Ang University College of Medicine, Gwangmyeong, Korea.

Förderung

  • National Research Foundation of Korea
  • Ministry of Education
  • National IT Industry Promotion Agency
  • Ministry of Science and ICT

Zitieren

APA

Lee, J. H., Lee, Y., Ko, K. J., Chung, M. J., Lee, C. U., Kim, J. H., & Han, D. H. (2025). Deep Learning-Based Uroflowmetry Curve Analysis Improves the Noninvasive Diagnosis of Lower Urinary Tract Symptoms. International Neurourology Journal, 29(Suppl 2), S73-S82. https://doi.org/10.5213/inj.2550266.133

Vancouver

Lee JH, Lee Y, Ko KJ, Chung MJ, Lee CU, Kim JH, et al. Deep Learning-Based Uroflowmetry Curve Analysis Improves the Noninvasive Diagnosis of Lower Urinary Tract Symptoms. International Neurourology Journal. 2025;29(Suppl 2):S73-S82. doi:10.5213/inj.2550266.133

BibTeX
@article{Lee2025,
  author = {Lee, Jong Hoon and Lee, Yungon and Ko, Kwang Jin and Chung, Myung Jin and Lee, Chung Un and Kim, Jung Hyun and Han, Deok-Hyun},
  title = {Deep Learning-Based Uroflowmetry Curve Analysis Improves the Noninvasive Diagnosis of Lower Urinary Tract Symptoms},
  journal = {International Neurourology Journal},
  year = {2025},
  volume = {29},
  number = {Suppl 2},
  pages = {S73--S82},
  doi = {10.5213/inj.2550266.133}
}