A Prospective Comparative Study of Mobile Acoustic Uroflowmetry and Conventional Uroflowmetry
International Neurourology Journal · 31.12.2021 · 25 (4) · 355-363
DOI: 10.5213/inj.2142154.077 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Neurourology Journal, erschienen am 31.12.2021. Verfasst von Dong-Gi Lee und 6 weiteren Autor:innen. Beteiligte Einrichtung: Division of Pediatric Urology, Department of Surgery, Texas Children's Hospital, and Scott Department of Urology, Baylor College of Medicine, Houston…. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 3.0). Gefördert von: Asan Institute for Life Sciences, Asan Medical Center.
Abstract (Originalsprache)
Purpose
The aim of this study was to assess the performance of a mobile acoustic Uroflowmetry (UFM) application compared with standard UFM in the pediatric population.
Methods
A mobile acoustic UFM application represents a noninvasive method to estimate the urine flow rate by recording voiding sounds with a smartphone. Male pediatric patients who were undergoing UFM testing were prospectively recruited, and the voiding sounds were recorded and analyzed. The intraclass correlation coefficient (ICC) was used to compare the maximum flow rate (Qmax), average flow rate (Qavg), voiding time (VT), and voiding volume (VV) as estimated by acoustic UFM with those calculated by standard UFM. Differences in Qmax, Qavg, VT, and VV between the 2 UFM tests were determined using 95% Bland-Altman limits of agreement.
Results
A total of 16 male patients were evaluated. Their median age was 9 years. With standard UFM, the median Qmax, Qavg, VT, and VV were 18.7 mL/sec, 11.1 mL/sec, 15.2 seconds, and 157.8 mL, respectively. Strong correlations were observed between the 2 methods for Qmax (ICC=0.755, P=0.005), VT (ICC=0.974, P
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Pediatric Urology, Department of Surgery, Texas Children's Hospital, and Scott Department of Urology, Baylor College of Medicine, Houston, TX, USA.
- Department of Urology, Kyung Hee University School of Medicine, Seoul, Korea.
- Department of Urology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.
Förderung
- Asan Institute for Life Sciences, Asan Medical Center
Zitieren
APA
Lee, D. G., Gerber, J., Bhatia, V., Janzen, N., Austin, P. F., Koh, C. J., & Song, S. H. (2021). A Prospective Comparative Study of Mobile Acoustic Uroflowmetry and Conventional Uroflowmetry. International Neurourology Journal, 25(4), 355-363. https://doi.org/10.5213/inj.2142154.077
Vancouver
Lee DG, Gerber J, Bhatia V, Janzen N, Austin PF, Koh CJ, et al. A Prospective Comparative Study of Mobile Acoustic Uroflowmetry and Conventional Uroflowmetry. International Neurourology Journal. 2021;25(4):355-363. doi:10.5213/inj.2142154.077
BibTeX
@article{Lee2021,
author = {Lee, Dong-Gi and Gerber, Jonathan and Bhatia, Vinaya and Janzen, Nicolette and Austin, Paul F and Koh, Chester J and Song, Sang Hoon},
title = {A Prospective Comparative Study of Mobile Acoustic Uroflowmetry and Conventional Uroflowmetry},
journal = {International Neurourology Journal},
year = {2021},
volume = {25},
number = {4},
pages = {355--363},
doi = {10.5213/inj.2142154.077}
}
EUVIMED